Research Article

Comprehensive Analysis of Small Disturbance Stability for Grid-Connected Wind Power System

Xinyu Cui1,*, Ziwen Li2, Yiming Liu3
1. School of International Education, Guangdong University of Technology, Guangzhou 511495, China
2. College of Automation and Electronic Engineering, Qingdao University of Science and Technology, Qingdao 266061, China
3. School of Mechanical, Electrical and Information Engineering, Xiamen Institute of Technology, Xiamen 361021, China

* Corresponding author: [email protected]

Abstract

Under the impact of the fossil energy crisis and global warming, thermal power, which dominates the old energy structure, is being criticized, and the government's strategy of ‘peak carbon and carbon neutrality’ has made new energy sources, represented by wind and solar power, more and more optimal choices on the path of energy transformation. One more proven renewable energy source with potential for widespread use is wind power. In addition to new development opportunities and problems brought about by the energy transition aim, the grid-connected wind power collection system (GCWPCS) must also contend with small disturbance oscillation (SDO), which adversely affects the performance of the power system. This research examines the small disturbance stability (SDS) of GCWPCS. It investigates the SDS analysis method and mechanism from two viewpoints, summarizes the benefits and drawbacks of previous research findings, and projects where the field of SDS of GCWPCS will go in the future.

Keywords: Wind power generation; power grid; stability analysis; mechanism
Published: January 7, 2025
DOI: 10.54254/2755-2721/2025.19581
Volume: ACE Vol.123
pp. 106-118
Download PDF

References

  1. Y. Zhu et al., "Novel Fast-Speed Partial-Shading-Tolerant Flexible Power Point Tracking for Photovoltaic Systems With Explicit Key Points Estimation," in IEEE Transactions on Sustainable Energy, vol. 15, no. 1, pp. 466-485, 2024.
  2. China Energy Media Group Co., Ltd. China Energy Big Data Report. Available: https://yb.1qh.cn/reports/2024-06-27/837a32825a 42ba07eda081d285d6bef4f038eef2.pdf (2024-06-27).
  3. J. Liu et al., "Impact of Power Grid Strength and PLL Parameters on Stability of Grid-Connected DFIG Wind Farm," IEEE Transactions on Sustainable Energy, vol. 11, no. 1, pp. 545-557, 2020.
  4. W. Du and H. Wang. "Small-Signal Stability of a Single Grid-Connected DFIG System." Analysis of Power System Sub/Super-Synchronous Oscillations Caused by Grid-Connected Wind Power Generation. Cham: Springer International Publishing, pp. 113-183, 2023.
  5. L. Kong, Y. Xue, L. Qiao and F. Wang, "Review of Small-Signal Converter-Driven Stability Issues in Power Systems," IEEE Open Access Journal of Power and Energy, vol. 9, pp. 29-41, 2022.
  6. L. Fan, C. Zhu, Z. Miao and M. Hu, "Modal Analysis of a DFIG-Based Wind Farm Interfaced With a Series Compensated Network," IEEE Transactions on Energy Conversion, vol. 26, no. 4, pp. 1010-1020, 2011.
  7. X. Xie, X. Zhang, H. Liu, H. Liu, Y. Li and C. Zhang, "Characteristic Analysis of Subsynchronous Resonance in Practical Wind Farms Connected to Series-Compensated Transmissions," in IEEE Transactions on Energy Conversion, vol. 32, no. 3, pp. 1117-1126, Sept. 2017.
  8. M. Beza and M. Bongiorno, "On the Risk for Subsynchronous Control Interaction in Type 4 Based Wind Farms," IEEE Transactions on Sustainable Energy, vol. 10, no. 3, pp. 1410-1418, July 2019.
  9. H. Liu et al., "Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks," IEEE Transactions on Power Systems, vol. 32, no. 6, pp. 4708-4720, Nov. 2017.
  10. M. Zhang, S. Xiao, T. Tian, et. al. "Analysis of SSO Influencing Factors and Parameter Adjustment for Grid-Connected Full-Converter Wind Farm Based on Impedance Sensitivity, " Power System Technology, vol. 42, no. 9, pp. 2768-2777, 2018.
  11. B. Shao, S. Zhao, J. Pei, et al. "Subsynchronous Oscillation Characteristic Analysis of Grid-connected DDWFs Via VSC-HVDC System. Power System Technology," vol. 43, no. 9, pp. 3344-3352, 2019.
  12. X. Guo, Y. Li, X. Xie, et al. "Sub-synchronous oscillation characteristics caused by PMSG-based wind plant farm integrated via flexible HVDC system," Proceedings of the CSEE, vol. 40, no. 4, pp. 1149-1160, 2020.
  13. Sun K, Yao W, Wen J. "Mechanism and characteristics analysis of subsynchronous oscillation caused by DFIG-based wind farm integrated into grid through VSC-HVDC system," Proceedings of the CSEE, vol. 38, no. 22, pp. 6520-6533, 2018.
  14. W. Du, C. Chen and H. Wang, "Subsynchronous Interactions Induced by DFIGs in Power Systems Without Series Compensated Lines," IEEE Transactions on Sustainable Energy, vol. 9, no. 3, pp. 1275-1284, 2018.
  15. K. M. Alawasa, Y. A. -R. I. Mohamed and W. Xu, "Active Mitigation of Subsynchronous Interactions Between PWM Voltage-Source Converters and Power Networks," IEEE Transactions on Power Electronics, vol. 29, no. 1, pp. 121-134, 2014,
  16. W. Du, X. Chen and H. Wang, "PLL-Induced Modal Resonance of Grid-Connected PMSGs With the Power System Electromechanical Oscillation Modes," IEEE Transactions on Sustainable Energy, vol. 8, no. 4, pp. 1581-1591, 2017.