Investigating safety precautions for linking photovoltaic and wind power generation to the grid
Abstract
The grid integration of renewable energy sources such as solar and wind power has received significant research attention, however, there remains a vast scope for exploration and improvement. Specifically, the discourse around relay protection and safety automatic devices in these power generation methods has been somewhat limited during the grid connection process. This article endeavors to investigate the technical obstacles encountered by photovoltaic and wind power grid protection mechanisms and crucial equipment, amidst the steady growth of renewable energy’s share in the power grid. This exploration is considered advantageous. The aim is to study and summarize existing research on protective measures and automation equipment for photovoltaic and wind power generation during grid connection, to promote technological innovation and development in this field. This paper critically assesses studies conducted so far on the topic of relay protection and automation hardware used in grid-connected solar and wind power generation, underscoring the significance of different protection techniques and their pivotal roles in ensuring system safety during grid connectivity. It then dives into the present obstacles and constraints that these technologies contend with. In conclusion, it suggests a few potential areas and anticipations for prospective research.
References
- Liang Huamin. Research on Fault Characteristics of Distribution Network Considering the Impact of Photovoltaic Connection Capacity [D]. Nanjing University of Posts and Telecommunications, 2022.
- Malone Research on the longitudinal protection of new energy generation grid connection lines [D]. Xi’an University of Technology,2023.
- Wu Zhengrong, Wang Gang, Li Haifeng, et al. Analysis of phase to phase short circuit faults in distributed power distribution networks [J]. Journal of China Electrical Engineering, 2013, 33(01):130-136.
- Kong Xiangping, Zhang Zhe, Yin Xianggen, et al. Research on Fault Current Characteristics and Fault Analysis Methods of Power Grid with Inverted Distributed Power Sources [J]. Journal of China Electrical Engineering, 2013,33(34):65-74+13.
- Shen Nanxuan Fault characteristics analysis and protection strategy research for grid connected operation of wind farms [D]. North China Electric Power University, 2018.
- Sadeghi H. A novel method for adaptive distance protection of transmission line connected to wind farms[J]. International Journal of Electrical Power & Energy Systems, 2012, 43(1):1376-1382.
- Pradhan A K, Joos G. Adaptive Distance Relay Setting for Lines Connecting Wind Farms[J]. IEEE Transactions on Energy Conversion, 2007, 22(1):206-213.
- Liu Scientific Research, Liu Yongmei, Sheng Wanxing, et al. Calculation Method for Maximum Admittance Capacity of Distributed Power Sources Connected to Distribution Networks Considering Voltage Constraints [J]. Power Automation Equipment,2016,36(06):81-87.
- Wang Chenqing, Song Guobing, Tang Haiyan, etc Adaptability analysis of distance protection in wind power access systems [J] Power System Automation, 2015(22):10-15.
- Nan Dongliang, Wang Weiqing, Peng Yinzhang, et al. Study on the optimal installation position and parameter configuration of fault current limiters in new energy grid connection [J]. Journal of Solar Energy, 2022,43(01):307-312.
- Tsimtsios A M, Safigianni A S, Nikolaidis V C. Generalized distance-based protection design for DG integrated MV radial distribution networks-Part Ⅰ: Guidelines[J]. Electric power systems research, 2019, 176(Nov.):105949.1-105949.16.