The commonly used methods for ECG Power-line interference removal

Xiao Li*
Anhui University

* Corresponding author: [email protected]

Abstract

The amplitude of electrocardiogram (ECG) signals is on the millivolt level, and is susceptible to interference from human respiration, muscle tremors, and device circuits during the acquisition process, resulting in baseline drift, electromyographic (EMG) interference, and power line interference. Power line interference is a significant noise source in physiological signal acquisition among these. This article explores several methods to reduce the impact of power frequency interference. By analyzing wavelet transforms, adaptive filtering, and smoothing filters, commonly used methods are evaluated to determine their advantages and limitations. Experimental results show that the smoothed filtering method produces the highest SNR and lowest MSE of the electrocardiogram signal after denoising, resulting in the best denoising effect and thorough filtering. The denoising effect of wavelet transform and adaptive filter is poor. But the different methods for power line interference elimination should be applied according to the data acquisition requirements and equipment performance in response to different situations.

Keywords: ECG; power-line Interference; wavelet threshold; adaptive notch filter; smoothing filtering.
Published: September 25, 2023
DOI: 10.54254/2755-2721/11/20230270
Volume: ACE Vol.11
pp. 289-295
Download PDF

References

  1. Wong M H, Louie J and Chun Y 2021 A priori dietary patterns and cardiovascular disease incidence in adult population-based studies: a review of recent evidence Crit. Rev. Food Sci. Nutr. 62(22) p 11-16 doi: 10.1080/10408398.2021.1897517.
  2. Veer K, Mathur P and Sharma T 2022 ECG for Cardiovascular Diseases Using Soft Computing Algorithms Current Signal Transduction Therapy 17(3)
  3. Kair M A and Shahnaz C 2012 Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains Biomed. Sig. Process. Control 7(5) p 481-489 doi: 10.1016/j.bspc.2011.11.003.
  4. Yang C, Nie C, Che M, Ruan X and Fan R 2020 Evaluation and Analysis of Ecg Denoising Effect Comp. Eng. Appl. 58(01) p 300-312
  5. Zhang J 2017 Research on Denoising of ECG Signals Based on Wavelet Transform Comp. Knowl. Tech. 13(31) p 227-229
  6. Singh O and Sunkaria R K 2017 ECG signal denoising via empirical wavelet transform Australas Phys. Eng. Sci. Med. 40 p 219–229 doi: 10.1007/s13246-016-0510-6.
  7. Sameni R 2017 Online filtering using piecewise smoothness priors: Application to normal and abnormal electrocardiogram denoising Signal Process. 133 p 52-63 doi: 10.1016/j.sigpro.2016.10.019.
  8. Jenitta J and Rajeswari A 2013 Denoising of ECG signal based on improved adaptive filter with EMD and EEMD IEEE Conf. Inf. Commun. Tech. p 957-962 doi: 10.1109/CICT.2013.6558234.
  9. Jenkal W, Latif R, Toumanari A, Dliou A, B'Charri O and Maoulainine F M R 2016 An efficient algorithm of ECG signal denoising using the adaptive dual threshold filter and the discrete wavelet transform Biocybern. Biomed. Eng. 36(3) p 499-508 doi: 10.1016/j.bbe.2016.04.001.
  10. Li Y and Guo F 2023 Estimation and Elimination of ECG Dual Frequency Interference by LMS Adaptive Filter Safety & EMC 01 p 66-71