Interface Pressure Optimization for a Lower Limb Assistive Exoskeleton—Mechanical Modeling and Monte Carlo Simulation of Segmented Compliant Supports
Abstract
The effect of the straps and support structures of a lower limb gait assist exoskeleton on pressure at the skin and soft tissue interface is examined. Because muscle atrophy may alter how loads pass between the limb and the device, a quasi-static torque and contact model for a lateral knee support model was developed. The nominal model used an assistive torque of 8 N·m and a support spacing of 0.24 m. A narrow circumferential cuff, a wide circumferential cuff, and segmented compliant pads were compared using the Markov Chain Monte Carlo method. Assistive torque, support spacing, effective contact fraction, strap preload, and a local concentration factor were varied. Under the stated model assumptions, the segmented pad concept had a median mean pressure of 8.9 kPa, with a 95% simulation interval of 6.8 to 11.5 kPa. Its peak pressure proxy had a median of 11.7 kPa, with an interval of 8.5 to 16.1 kPa. The corresponding medians for the narrow cuff were 20.6 and 36.9 kPa. Based on the comparison, an open, segmented load-bearing pad is proposed and bench testing on a limb surrogate is recommended. In the future, this study has implications on wearable pressure limits for older adults.
References
- De Rossi, S. M. M., Vitiello, N., Lenzi, T., Ronsse, R., Koopman, B., Persichetti, A., Vecchi, F., Ijspeert, A. J., van der Kooij, H., & Carrozza, M. C. (2011). Sensing pressure distribution on a lower-limb exoskeleton physical human-machine interface.Sensors, 11, 207–227. https://doi.org/10.3390/s110100207.
- Tamez-Duque, J., Cobian-Ugalde, R., Kilicarslan, A., Venkatakrishnan, A., Soto, R., & Contreras-Vidal, J. L. (2015). Real-time strap pressure sensor system for powered exoskeletons.Sensors, 15, 4550–4563. https://doi.org/10.3390/s150204550.
- Massardi, S., Rodriguez-Cianca, D., Pinto-Fernández, D., Moreno, J. C., Lancini, M., & Torricelli, D. (2022). Characterization and evaluation of human-exoskeleton interaction dynamics: A review.Sensors, 22, 3993. https://doi.org/10.3390/s22113993.
- Shushtari, M., et al. (2024). Human-exoskeleton interaction portrait.Journal of NeuroEngineering and Rehabilitation, 21, 133. https://doi.org/10.1186/s12984-024-01447-1.
- Kermavnar, T., O'Sullivan, K. J., Casey, V., de Eyto, A., & O'Sullivan, L. W. (2020). Circumferential tissue compression at the lower limb during walking, and its effect on discomfort, pain and tissue oxygenation: Application to soft exoskeleton design.Applied Ergonomics, 86, 103093. https://doi.org/10.1016/j.apergo.2020.103093.
- Kermavnar, T., Power, V., de Eyto, A., & O'Sullivan, L. Cuff pressure algometry in patients with chronic pain as guidance for circumferential tissue compression for wearable soft exoskeletons: A systematic review.Soft Robotics, 5, 497–511. https://doi.org/10.1089/soro.2017.0088.
- Armitage, L., Turner, S., & Sreenivasa, M. Human-device interface pressure measurement in prosthetic, orthotic and exoskeleton applications: A systematic review.Medical Engineering & Physics, 97, 56–69. https://doi.org/10.1016/j.medengphy.2021.09.008.
- Kermavnar, T., O'Sullivan, K. J., de Eyto, A., & O'Sullivan, L. W. Relationship between interface pressures and pneumatic cuff inflation pressure at different assessment sites of the lower limb to aid soft exoskeleton design.Human Factors, 63, 101–114. https://doi.org/10.1177/0018720820908758.
- Sanchez-Villamañan, M. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. Compliant lower limb exoskeletons: A comprehensive review on mechanical design principles.Journal of NeuroEngineering and Rehabilitation, 16, 55. https://doi.org/10.1186/s12984-019-0517-9.
- Kermavnar, T., O'Sullivan, K. J., de Eyto, A., & O'Sullivan, L. W. Discomfort/pain and tissue oxygenation at the lower limb during circumferential compression: Application to soft exoskeleton design.Human Factors, 62, 470–484. https://doi.org/10.1177/0018720819892098.
- Bessler, J., Prange-Lasonder, G. B., Schaake, L., Saenz, J. F., Bidard, C., Fassi, I., Valori, M., Lassen, A. B., & Buurke, J. H. (2021). Safety assessment of rehabilitation robots: A review identifying safety skills and current knowledge gaps.Frontiers in Robotics and AI, 8, 602878. https://doi.org/10.3389/frobt.2021.602878.
- International Organization for Standardization. (2020). ISO/TR 23482-1:2020 robotics-application of ISO 13482-part 1: Safety-related test methods. ISO.
- Wang, T., et al. (2022). A review on the rehabilitation exoskeletons for the lower limbs of the elderly and the disabled.Electronics, 11, 388. https://doi.org/10.3390/electronics11030388.
- Lowe, B. D., Billotte, W. G., & Peterson, D. R. (2019). ASTM F48 formation and standards for industrial exoskeletons and exosuits.IISE Transactions on Occupational Ergonomics and Human Factors, 7, 230–236. https://doi.org/10.1080/24725838.2019.1579769.