Buildings with heritage suffer from various disturbances like hygrothermal disturbances, moisture, vibration, and crack problems which cannot be easily identified from sensor readings independently. In this research, a multi-source sensing-based digital twin is developed for identifying environmental risks dynamically in a monitored two-story building made of bricks and timber structure. Variables such as temperature, relative humidity, wall moisture, vibration, crack displacement, and weather data outside are synchronized every five minutes and mapped into IFC-based Heritage Building Information Model in Unity. With the Temporal Fusion Transformer, a multivariate history with 24 time steps is taken into account, and normal, hygrothermal instability, moisture infiltration, vibration abnormalities, and crack displacement risk predictions are done. The architecture includes class weights, adaptive temporal consistency, and spatial regularization of components. With temporal testing, macro-F1 of 0.891±0.012, AUROC of 0.962±0.006, and mean warning delay of 6.7±1.1 min were obtained which is better than LSTM and XGBoost models with p<0.001. Removal of moisture sensors yielded maximum drop of macro-F1 to 0.847±0.014. Digital twin localization error was 0.43±0.17 m.

Keywords: historic buildings; digital twin; environmental risk; multi-source sensing; Temporal Fusion Transformer
Published: November 3, 2026
DOI: 10.54254/2755-2721/2026.38639
Volume: ACE Vol.278
pp. 162-167
Download PDF

References

  1. Vuoto, A., Funari, M. F., & Lourenço, P. B. (2024). Shaping digital twin concept for built cultural heritage conservation: A systematic literature review.International Journal of Architectural Heritage, 18(11), 1762–1795.
  2. Niccolucci, F., & Felicetti, A. (2024). Digital twin sensors in cultural heritage ontology applications.Sensors, 24(12), 3978.
  3. Malovrh Rebec, K., Deanovič, B., & Oostwegel, L. (2022). Old buildings need new ideas: Holistic integration of conservation-restoration process data using Heritage Building Information Modelling.Journal of Cultural Heritage, 55, 30–42.
  4. Muradov, M., Kot, P., Markiewicz, J., Łapiński, S., Tobiasz, A., Onisk, K., Shaw, A., Hashim, K., Zawieska, D., & Mohi-Ud-Din, G. (2022). Non-destructive system for in-wall moisture assessment of cultural heritage buildings.Measurement, 203, 111930.
  5. Cabello-Briones, C., Verichev, K., & Prieto, A. J. (2022). Digital fuzzy control system for monitoring environmental conditions and technical suitability of shelters at archaeological sites.Journal of Cultural Heritage, 57, 226–234.
  6. Kong, X., & Hucks, R. G. (2023). Preserving our heritage: A photogrammetry-based digital twin framework for monitoring deteriorations of historic structures.Automation in Construction, 152, 104928.
  7. Cheng, J. C. P., Zhang, J., Kwok, H. H. L., & Tong, J. C. K. (2024). Thermal performance improvement for residential heritage building preservation based on digital twins.Journal of Building Engineering, 82, 108283.
  8. Yiğit, A. Y., & Uysal, M. (2024). Automatic crack detection and structural inspection of cultural heritage buildings using UAV photogrammetry and digital twin technology.Journal of Building Engineering, 94, 109952.
  9. Cecere, L., Colace, F., Lorusso, A., Messina, B., Tucker, A., & Santaniello, D. (2024). IoT and digital twin: A new perspective for cultural heritage predictive maintenance.Procedia Structural Integrity, 64, 2181–2188.
  10. Zheng, P., Zhou, H., Liu, J., & Nakanishi, Y. (2023). Interpretable building energy consumption forecasting using spectral clustering algorithm and temporal fusion transformers architecture.Applied Energy, 349, 121607.