Abstract

The use of wide-bandgap power devices in solid-state transformers enables higher switching frequencies and power densities, but it also exposes medium-frequency transformer insulation to fast repetitive voltage pulses. Short rise times, high dv/dt, high repetition frequencies, and harmonic content can produce nonuniform winding voltages, local field enhancement, and partial discharge. This review examines the resulting insulation stress, discharge mechanisms, detection methods, relevant IEC standards, and design approaches. The reviewed studies show that partial discharge inception and insulation lifetime depend on voltage amplitude, rise time, repetition frequency, polarity, temperature, and residual charge. They also show that power-frequency test results cannot be transferred directly to pulse-width modulation service. Reliable insulation assessment therefore requires complete waveform reporting, interference-resistant sensing, and product-specific test procedures. The resulting evidence should then guide an insulation design that combines electric-field control and thermal management while accounting for parasitic parameters and manufacturing tolerances. Future work should establish common test waveforms and relate discharge activity to long-term material damage under representative operating duty.

Keywords: solid-state transformer; medium-frequency transformer; fast repetitive pulses; partial discharge
Published: October 27, 2026
DOI: 10.54254/2755-2721/2026.38200
Volume: ACE Vol.277
pp. 193-200
Download PDF

References

  1. Mocevic, S., Yu, J., Fan, B., et al. (2022). Design of a 10 kV SiC MOSFET-based high-density, high-efficiency, modular medium-voltage power converter.iEnergy, 1(1), 100–113. https://doi.org/10.23919/IEN.2022.0001
  2. Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023). High-frequency transformer design with medium-voltage insulation for resonant converter in solid-state transformer.IEEE Transactions on Power Electronics, 38(8), 9917–9932. https://doi.org/10.1109/TPEL.2023.3279030
  3. Cremasco, A., Rothmund, D., Curti, M., & Lomonova, E. A. (2022). Voltage distribution in the windings of medium-frequency transformers operated with wide bandgap devices.IEEE Journal of Emerging and Selected Topics in Power Electronics, 10(4), 3587–3602. https://doi.org/10.1109/JESTPE.2021.3064702
  4. Guo, Z., Huang, A. Q., Hebner, R. E., Montanari, G. C., & Feng, X. (2022). Characterization of partial discharges in high-frequency transformer under PWM pulses.IEEE Transactions on Power Electronics, 37(9), 11199–11208. https://doi.org/10.1109/TPEL.2022.3169747
  5. Agarwal, R., Li, H., Guo, Z., & Cheetham, P. (2023). The effects of PWM with high dv/dt on partial discharge and lifetime of medium-frequency transformer for medium-voltage (MV) solid state transformer applications.IEEE Transactions on Industrial Electronics, 70(4), 3857–3866. https://doi.org/10.1109/TIE.2022.3174243
  6. Wang, Z., Wei, X., Bak, C. L., et al. (2025). Partial discharge behavior of high frequency transformer insulation under high voltage PWM stress.IEEE Transactions on Power Electronics, 40(9), 13142–13156. https://doi.org/10.1109/TPEL.2025.3566999
  7. Naderiallaf, H., Giangrande, P., & Galea, M. (2023). Characterization of PDIV, PDEV, and RPDIV in insulated wires under unipolar repetitive square wave excitations for inverter-fed motors.IEEE Access, 11, 51047–51063. https://doi.org/10.1109/ACCESS.2023.3279886
  8. Chen, B., Hu, Y., Wu, L., & Li, H. (2023). Partial discharge pulse extraction and interference suppression under repetitive pulse excitation using time-reassigned multisynchrosqueezing transform.IEEE Transactions on Instrumentation and Measurement, 72, Art. no. 3535609, 1–9. https://doi.org/10.1109/TIM.2023.3325519
  9. International Electrotechnical Commission. (2024).Electrical insulating materials and systems—Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses(3rd ed.).
  10. International Electrotechnical Commission. (2025).High-voltage test techniques—Charge-based measurement of partial discharges(4th ed.).
  11. Guillod, T., Krismer, F., & Kolar, J. W. (2017). Electrical shielding of MV/MF transformers subjected to high dv/dt PWM voltages. In2017 IEEE Applied Power Electronics Conference and Exposition (APEC). https://doi.org/10.1109/APEC.2017.7931050
  12. Yi, Z., Sun, K., Liu, H., Cao, G., & Lu, S. (2022). Design and optimization of the insulation of medium-voltage medium-frequency transformers for solid-state transformers.IEEE Journal of Emerging and Selected Topics in Power Electronics, 10(4), 3561–3570. https://doi.org/10.1109/JESTPE.2021.3094674
  13. Chen, Q., Raju, R., Dong, D., & Agamy, M. (2018). High frequency transformer insulation in medium voltage SiC enabled air-cooled solid-state transformers. In2018 IEEE Energy Conversion Congress and Exposition (ECCE)(pp. 2436–2443). https://doi.org/10.1109/ECCE.2018.8557849
  14. Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021). Design and optimization of a 200-kW medium-frequency transformer for medium-voltage SiC PV inverters.IEEE Transactions on Power Electronics, 36(9), 10548–10560. https://doi.org/10.1109/TPEL.2021.3059879
  15. Guo, Z., Rajendran, S., Tangudu, J., et al. (2023). A novel high insulation 100 kW medium frequency transformer.IEEE Transactions on Power Electronics, 38(1), 112–117. https://doi.org/10.1109/TPEL.2022.3205646