Microfluidic Pre-processing Integrated Smart Lateral Flow Immunochromatographic Chip for Quantitative Analysis of Complex Samples
Abstract
A microfluidic pre-processing integrated, smart lateral flow immunochromatographic chip is developed herein for quantitative analysis of complex samples. In this study, c-reactive protein (CRP) is chosen as the biomarker, while human whole blood serves as the matrix of interest. The proposed chip combines several functionalities, namely plasma separation, buffer mixing, lateral flow immunochromatographic detection, and smartphone readout, all in one process chain. The design is carried out with the aid of AutoCAD 2024 software, simulation performed by COMSOL Multiphysics 6.1, fabrication by means of PDMS soft lithography, and data analysis by using Python 3.11 equipped with OpenCV. CRP standards (0, 1, 5, 10, 25, and 50 mg/L) spiked in human whole blood with an appropriate anti-coagulant were used to establish the performance characteristics of the chip. Moreover, anonymous human serum was used for comparison against enzyme-linked immunosorbent assay (ELISA). The findings show that the mean flow time and plasma separation efficiency values are 168.4 ± 14.7 s and 87.6 ± 4.3%, respectively. The chip showed a detection range of 1-50 mg/L with R² = 0.986 and the limit of detection value was found to be 0.72 mg/L. The repeatability was acceptable as indicated by a variation coefficient less than 8% both intra- and inter-batches. Moreover, results showed excellent agreement between ELISA and the proposed chip (r = 0.963).
References
- Dey, M. K., Iftesum, M., Devireddy, R., & Gartia, M. R. (2023). New technologies and reagents in lateral flow assay (LFA) designs for enhancing accuracy and sensitivity.Analytical Methods, 15, 4351–4376.
- Wang, Y., Nunna, B. B., Talukder, N., Etienne, E. E., & Lee, E. S. (2021). Blood plasma self-separation technologies during the self-driven flow in microfluidic platforms.Bioengineering, 8(7), 94.
- Tavakolidakhrabadi, A., Stark, M., Küenzi, A., Carrara, S., & Bessire, C. (2025). Optimized microfluidic biosensor for sensitive C-reactive protein detection.Biosensors, 15(4), 214.
- Boonkaew, S., Szot-Karpińska, K., Niedziółka-Jönsson, J., de Marco, A., & Jönsson-Niedziółka, M. (2024). NFC smartphone-based electrochemical microfluidic device integrated with nanobody recognition for C-reactive protein.ACS Sensors, 9(6), 3066–3074.
- Park, J. (2022). Lateral flow immunoassay reader technologies for quantitative point-of-care testing.Sensors, 22(19), 7398.
- Aryal, P., & Henry, C. S. (2024). Advancements and challenges in microfluidic paper-based analytical devices: Design, manufacturing, sustainability, and field applications.Frontiers in Lab on a Chip Technologies, 3, 1467423.
- Hong, D., Kim, K., Jo, E. J., & Kim, M. G. (2021). Electrochemiluminescence-incorporated lateral flow immunosensors using Ru(bpy)₃²⁺-labeled gold nanoparticles for the full-range detection of physiological C-reactive protein levels.Analytical Chemistry, 93(22), 7925–7932.
- Colombo, M., Bezinge, L., Rocha Tapia, A., Shih, C.-J., deMello, A. J., & Richards, D. A. (2023). Real-time, smartphone-based processing of lateral flow immunoassays.Sensors & Diagnostics, 2, 100–110.
- Chen, S.-J., Lu, S.-Y., Tseng, C.-C., Huang, K.-H., Chen, T.-L., & Fu, L.-M. (2024). Rapid microfluidic immuno-biosensor detection system for the point-of-care determination of high-sensitivity urinary C-reactive protein.Biosensors, 14(6), 283.
- Zhang, S., Guo, J., Wang, Z., Li, X., & Liu, Y. (2023). A quantitative detection algorithm for multi-test line lateral flow immunoassay based on smartphone image processing.Sensors, 23(14), 6401.