Research Article

Assistive Input Device for Users with Limb Impairments

Xuanting Chen*
Shenzhen College of International Education

* Corresponding author: [email protected]

Abstract

Individuals with severe limb impairments encounter substantial barriers during human‑computer interaction, while commercially available assistive input devices are often prohibitively expensive. This paper presents a low‑cost wearable assistive input device (bill‑of‑materials cost < ¥130) built around the nRF52832 Bluetooth‑Low‑Energy (BLE) system‑on‑chip and an MPU‑6050 inertial measurement unit. A real‑time‑clock‑based asynchronous event‑driven architecture reduces power consumption, and the sensor's on‑chip 5 Hz digital low‑pass filter suppresses involuntary muscle tremor at the signal source. A multi‑threaded PC‑side client maps real‑time posture data to discrete keyboard commands. A user study with three participants exhibiting distinct physiological profiles was carried out under two interaction modes. In discrete click‑trigger mode, the system achieved a peak directional‑selection throughput of 12 WPM, while continuous dwell‑hold control yielded an average throughput of 4.2 WPM. The participant with a full, unrestricted range‑of‑motion (ROM) reached a trigger accuracy of 98.2 %, whereas the participant with severely‑restricted head movement obtained only 64.0 % accuracy. Experimental results demonstrate that fixed‑cutoff on‑chip filtering carries inherent performance limitations for users with extremely limited motion range. Directions for future work include adaptive filtering algorithms and multi‑modal interaction schemes.

Keywords: assistive technology; wearable input device; human‑computer interaction; inertial measurement unit (IMU); Bluetooth Low Energy (BLE); head‑motion tracking; tremor suppression
Published: September 22, 2026
DOI: 10.54254/2755-2721/2026.AST37057
Volume: ACE Vol.265
pp. 48-55
Download PDF

References

  1. Betke, M., Gips, J., & Fleming, P. (2002). The camera mouse: Visual tracking of body features to provide computer access for people with severe disabilities.IEEE Transactions on Neural Systems and Rehabilitation Engineering, 10(1), 1-10. https://doi.org/10.1109/TNSRE.2002.1021581
  2. Barea, R., Boquete, L., Mazo, M., & Lopez, E. (2002). System for assisted mobility using eye movements based on electrooculography.IEEE Transactions on Neural Systems and Rehabilitation Engineering, 10(4), 209-218. https://doi.org/10.1109/TNSRE.2002.806829
  3. Raya, R., Rocon, E., Ceres, R., Harlaar, J., & Geytenbeek, J. (2011). Characterizing head motor disorders to create novel interfaces for people with cerebral palsy: Creating an alternative communication channel by head motion.2011 IEEE International Conference on Rehabilitation Robotics, 1-6. Zurich, Switzerland. https://doi.org/10.1109/ICORR.2011.5975409
  4. Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011). Estimation of IMU and MARG orientation using a gradient descent algorithm.2011 IEEE International Conference on Rehabilitation Robotics, 1-7. Zurich, Switzerland. https://doi.org/10.1109/ICORR.2011.5975346
  5. Choi, C., & Kim, J. (2007). A real-time EMG-based assistive computer interface for the upper limb disabled. In2007 IEEE 10th International Conference on Rehabilitation Robotics(pp. 459-462). Noordwijk, Netherlands. https://doi.org/10.1109/ICORR.2007.4428465
  6. Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007). Design and validation of a rehabilitation robotic exoskeleton for tremor assessment and suppression.IEEE Transactions on Neural Systems and Rehabilitation Engineering, 15(3), 367-378. https://doi.org/10.1109/TNSRE.2007.903917
  7. Siekkinen, M., Hiienkari, M., Nurminen, J. K., & Nieminen, J. (2012). How low energy is bluetooth low energy? Comparative measurements with ZigBee/802.15.4. In2012 IEEE Wireless Communications and Networking Conference Workshops (WCNCW)(pp. 232-237). Paris, France. https://doi.org/10.1109/WCNCW.2012.6215496