Research Article

Research Progress on Mechanical Systems of Rehabilitation Robots from the Perspective of Mechanical Engineering

Fumeng Liao*
Wuyi University

* Corresponding author: [email protected]

Abstract

The demand for rehabilitation exoskeletons has outpaced the mechanical engineering required to make them truly wearable. Demographic aging and rising stroke incidence have expanded the candidate patient pool, yet most devices still stall at the laboratory door because their physical hardware cannot reconcile the conflicting requirements of daily use: every gram saved from the limb tends to cost torque, every fixed-stiffness transmission eventually misaligns with anatomical joints, and every rigid actuator introduces a failure mode that exposes the patient to injury. These problems are not independent; they trace back to a single design tension—structure, drive, and sensing are still optimized separately rather than treated as one coupled interface. This review therefore narrows its scope to the mechanical layer, tracing recent advances in biomimetic structures, actuation architectures, and embedded sensing integration. Rather than covering control algorithms or clinical trials in isolation, this paper examines how structural choices constrain drive options and how drive options, in turn, dictate what sensing and feedback can realistically achieve. Particular attention is given to two under-addressed engineering gaps: long-term wearing comfort under cyclic loading, and the accumulation of nonlinear kinematic errors across multi-joint chains. The next generation of hardware will need to move beyond single-subsystem optimization toward adaptive stiffness, intrinsic mechanical safety, and high physical integration—shifts that are as much about design culture as about component performance.

Keywords: Rehabilitation exoskeleton; human-robot interaction; variable stiffness actuator; lightweight design; mechanical system
Published: May 25, 2026
DOI: 10.54254/2755-2721/2026.GU33779
Volume: ACE Vol.242
pp. 24-32
Download PDF

References

  1. Jiang, J., Chen, P., Peng, J., Qiao, X., Zhu, F., & Zhong, J. (2023). Design and Optimization of Lower Limb Rehabilitation Exoskeleton with a Multiaxial Knee Joint. Biomimetics, 8(2), 156. https: //doi.org/10.3390/biomimetics8020156
  2. W. Xu, Y. Guo, C. Bravo and P. Ben-Tzvi, "Design, Control, and Experimental Evaluation of a Novel Robotic Glove System for Patients With Brachial Plexus Injuries, " in IEEE Transactions on Robotics, vol. 39, no. 2, pp. 1637-1652, April 2023, doi: 10.1109/TRO.2022.3220973.
  3. Wang, T., Olivoni, E., Spyrakos-Papastavridis, E., O'Connor, R. J., and Dai, J. S. (December 6, 2021). "Novel Design of a Rotation Center Auto-Matched Ankle Rehabilitation Exoskeleton With Decoupled Control Capacity." ASME.  J. Mech. Des. May 2022; 144(5): 053301.  https: //doi.org/10.1115/1.4052842
  4. Y. Zhou  et al., "Design and preliminary validation of a compatible lower limb exoskeleton with variable stiffness actuation, "  Robotica, vol. 43, no. 5, pp. 1675–1690, 2025. doi: 10.1017/S0263574725000451
  5. Li, H.; Li, M.; Su, Y.; Xie, D.; Tong, R.K.-Y.; Yu, H. Biomimetic Design and Optimization of a Rolling-Gear Knee Exoskeleton for High Kinematic Fidelity and Efficiency. Machines 2025, 13, 997. https: //doi.org/10.3390/machines13110997
  6. Tian, M.; Liu, Y.; Chen, Z.; Wang, X.; Zhang, Q.; Liu, B. Biomimetic Design and Validation of an Adaptive Cable-Driven Elbow Exoskeleton Inspired by the Shrimp Shell. Biomimetics 2025, 10, 271. https: //doi.org/10.3390/biomimetics10050271
  7. Leone, S.; Lago, F.; Lavia, G.; Macrì, F.P.; Sgamba, F.; Tozzo, A.; Adamo, D.; Avila, J.M.N.; Carbone, G. Design and Experimental Validation of a Unidirectional Cable-Driven Exoskeleton for Upper Limb Rehabilitation. Appl. Sci. 2025, 15, 11996. https: //doi.org/10.3390/app152211996
  8. Vatan, H.; Theodoridis, T.; Wei, G.; Saffari, Z.; Holderbaum, W. The Design and Development of a Wearable Cable-Driven Shoulder Exosuit (CDSE) for Multi-DOF Upper Limb Assistance. Appl. Sci. 2025, 15, 10673. https: //doi.org/10.3390/app151910673
  9. Supriyono, C.S.A.; Dragusanu, M.; Malvezzi, M. A Comprehensive Review of Elbow Exoskeletons: Classification by Structure, Actuation, and Sensing Technologies. Sensors 2025, 25, 4263. https: //doi.org/10.3390/s25144263
  10. A. Choi, T. Hyong Kim, S. Chae and J. Hwan Mun, "Improved Transfer Learning for Detecting Upper-Limb Movement Intention Using Mechanical Sensors in an Exoskeletal Rehabilitation System, " in  IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 32, pp. 3953-3965, 2024, doi: 10.1109/TNSRE.2024.3486444.
  11. BU Lingyu, YIN Xiangguo, LIN Mingxing, et al. Motion intention recognition using surface electromyography and arrayed flexible thin-film pressure sensors. Journal of Measurement Science and Instrumentation, 2025, 16(4): 486-497. DOI: 10.62756/jmsi.1674-8042.2025047.
  12. AICHAOUI, M, & IKHLEF, A (2024). A cascade genetic algorithm based adaptive backstepping impedance control for upper limb rehabilitation robot.  Turkish Journal of Electrical Engineering and Computer Sciences 32  (6): 849-866.  https: //doi.org/10.55730/1300-0632.4106
  13. Rosales-Luengas, Y.; Salazar, S.; Rangel-Popoca, S.J.; Cortés-García, Y.; Flores, J.; Lozano, R. Active Gait Retraining with Lower Limb Exoskeleton Based on Robust Force Control. Appl. Sci. 2025, 15, 4032. https: //doi.org/10.3390/app15074032
  14. Guo, B.; Li, Z.; Huang, M.; Li, X.; Han, J. Patient's Healthy-Limb Motion Characteristic-Based Assist-As-Needed Control Strategy for Upper-Limb Rehabilitation Robots. Sensors 2024, 24, 2082. https: //doi.org/10.3390/s24072082