Research Article

The Effect of Liquid Cooling Flow Rate on the Temperature Field and Temperature Uniformity of Bottom-cooled Plate-type Power Battery Modules

Peike Li*
CUS University

* Corresponding author: [email protected]

Abstract

We investigated how liquid cooling flow rate influences the temperature field and temperature uniformity of a bottom-cooled plate-type power battery module. Fluent simulation results were compared for six inlet velocities, namely 0.1, 0.2, 0.4, 0.6, 0.8, and 1.0 m/s. The analysis did not rely on a single output image. Instead, the geometry, mesh quality, convergence history, and temperature contours were examined together so that the thermal behavior under each condition could be read in a consistent way. The maximum temperature, minimum temperature, and maximum temperature difference were then extracted from the contour scales and used as the main evaluation indices. The results show a stable vertical thermal gradient in the bottom-cooled configuration. The area close to the cooling plate remains cooler, while the upper part of the module retains a comparatively high temperature. As inlet velocity increases, the hot region in the upper section becomes smaller and the overall temperature level drops. The maximum temperature decreases from 336 K to 330 K, the minimum temperature stays close to 300 K, and the maximum temperature difference is reduced from 36 K to 30 K. The most noticeable improvement appears in the range of 0.1-0.6 m/s. Beyond that point, higher flow rate still helps, but the gain becomes small. In practical terms, flow-rate regulation can improve the thermal response of the module, yet it cannot by itself remove the upper-hot/lower-cool pattern created by bottom cooling. Further improvement in temperature uniformity will still depend on cold-plate design and on shortening the heat-transfer path inside the module.

Keywords: Power battery; Liquid cooling; Cold plate; Temperature field; Temperature uniformity; Numerical simulation
Published: May 11, 2026
DOI: 10.54254/2755-2721/2026.33400
Volume: ACE Vol.233
pp. 175-182
Download PDF

References

  1. He L, Gu Z, Zhang Y, et al. Review on thermal management of lithium-ion batteries for electric vehicles: advances, challenges, and outlook [J]. Energy & fuels, 2023, 37(7): 4835-4857.
  2. Rahmani A, Dibaj M, Akrami M. Recent advancements in battery thermal management systems for enhanced performance of Li-ion batteries: A comprehensive review [J]. Batteries, 2024, 10(8): 265.
  3. Zhou R, Chen Y, Zhang J, et al. Research progress in liquid cooling technologies to enhance the thermal management of LIBs [J]. Materials Advances, 2023, 4(18): 4011-4040.
  4. Zhao G, Wang X, Negnevitsky M, et al. An up-to-date review on the design improvement and optimization of the liquid-cooling battery thermal management system for electric vehicles [J]. Applied Thermal Engineering, 2023, 219: 119626.
  5. Anisha, Kumar A. Identification and mitigation of shortcomings in direct and indirect liquid cooling-based battery thermal management system [J]. Energies, 2023, 16(9): 3857.
  6. Xu J, Guo Z, Xu Z, et al. A systematic review and comparison of liquid-based cooling system for lithium-ion batteries [J]. ETransportation, 2023, 17: 100242.
  7. Murphy M, Akrami M. Advanced thermal management of cylindrical lithium-ion battery packs in electric vehicles: a comparative CFD study of vertical, horizontal, and optimised liquid cooling designs [J]. Batteries, 2024, 10(8): 264.
  8. Angani A, Kim H W, Hwang M H, et al. A comparison between Zig-Zag plated hybrid parallel pipe and liquid cooling battery thermal management systems for Lithium-ion battery module [J]. Applied Thermal Engineering, 2023, 219: 119599.
  9. Wang Z, Wang X, Liang G, et al. Topology optimization design and thermofluid performance analysis of li-ion battery cooling plate [J]. Structural and Multidisciplinary Optimization, 2024, 67(11): 198.
  10. Gu J, Kim H K, Jang S. Study of cooling performance of liquid-cooled ev battery module according to the Tim compression ratio [J]. International Journal of Automotive Technology, 2025, 26(2): 359-373.
  11. Chen Y, Hu Z. Computational fluid dynamic modeling of pack-level battery thermal management systems in electric vehicles [J]. Energies, 2025, 18(3): 484.
  12. Niu Z, Pang K, Pang B, et al. Orthogonal experimental-based thermal management design and simulation optimization of a liquid-cooled battery module [J]. Scientific Reports, 2025, 15(1): 33442.