Abstract

The accurate prediction of power losses in ultra-high-voltage (UHV) AC transmission systems is critical for ensuring the economic and efficient operation of modern power grids. This paper investigates the temperature-dependent fluctuations in line losses—particularly those induced by corona discharge—under varying ambient conditions. To this end, this paper proposes a comprehensive loss-prediction framework integrating Spearman rank correlation analysis with a particle swarm optimization–enhanced extra-trees (PSO-ET) model. The methodology is validated using operational data from 1000 kV UHV transmission projects in the Fujian–Zhejiang region. First, Spearman correlation analysis confirms temperature as the dominant meteorological factor influencing line losses. Subsequently, the PSO algorithm is employed to globally optimize three key hyperparameters of the ET model: tree count, maximum tree depth, and the humidity threshold used to dichotomize operating conditions into "dry" and "high-humidity" regimes. This enables precise decoupled training under distinct environmental states. Experimental results demonstrate that the proposed model achieves an average absolute error (MAE) of only 5.1315 MW on the independent test set. Further sensitivity analysis reveals that the gradient of line loss with respect to temperature peaks at approximately 7.6 °C—indicating a pronounced nonlinear response. Crucially, this inflection coincides with the onset of surface condensation, thereby uncovering a previously underappreciated surge effect: in low-temperature, high-humidity environments, condensation on conductor surfaces significantly amplifies corona losses. This study provides a robust, data-driven foundation for real-time loss monitoring and energy-efficient scheduling of UHV transmission lines under complex and dynamic meteorological conditions.

Keywords: introduction of UHV AC power transmission; prediction of corona losses; temperature; particle swarm optimization; spearman correlation coefficient
Published: March 30, 2026
DOI: 10.54254/2755-2721/2026.BJ32510
Volume: ACE Vol.214
pp. 7-17
Download PDF

References

  1. Yang, J., Xiao, D., Zhang, W., et al. (2020). Prediction of UHV Line Loss Based on RBFNN Optimized by Improved PSO. Guangdong Electric Power, 33(9), 85-91.
  2. Zhao, G., Li, X., Nie, G., et al. (2018). Loss characteristics of ultra high voltage alternating current dual circuit transmission line based on corona loss calculation. Science Technology and Engineering, 18(30), 177-182.
  3. Li, Y., Chai, X., Zhang, H., et al. (2013). Calculation of UHVDC bipolar split transmission line corona loss. Journal of Chongqing University, 36(3), 90-95.
  4. Li, X. (1985). Influencing factors of corona loss and radio interference of DC transmission lines. High Voltage Engineering, (1), 57-65.
  5. Liu, S., Zhang, X., Lei, X., et al. (2017). Lightning characteristics analysis of UHVDC transmission lines considering corona loss(in Chinese). Sichuan Electric Power Technology, 40(1), 55-57, 88.
  6. Wang, J. C. (2020). Research on Line Loss Calculation and Line Loss Anomaly Analysis of Transmission Line Based on Data Knowledge Fusion [Master's thesis]. South China University of Technology.
  7. Wang, B. L., & Sha, T. (2023). Analysis of Equivalent Physical Model Parameters and Corona Loss in High Altitude Regions of High Voltage Transmission Lines. Value Engineering, 42(24), 129-131.
  8. Huang, S. M., Jiang, L. G., Li, Z. C., et al. (2022). Corona Loss Prediction of UHV AC Transmission Line Based on DBN Neural Network Optimized by PSO. Electric Power, 55(06), 95-102.
  9. Yang, G. X., Lan, S., & Li, Z. C. (2023). Calculation Method for Loss of UHV AC Transmission Line Considering Corona Loss Under Different Weather Conditions. Electric Engineering, (19), 182-188.
  10. Li, M., Liu, L., Yu, Z. Q., et al. (2016). Prediction Method of Corona Inception Field Intensity for HVDC Line Fittings at 2 km Altitude. Southern Power System Technology, 10(09), 55-60.
  11. Zhu, N. N. (2011). Research of Equivalence of Corona Loss Measurements of the Conductors Based on Corona Cage and Test Line [Master's thesis]. North China Electric Power University.
  12. Yu, Q., Huo, X. D., He, J., et al. (2023). Trend Prediction of Power Blackout Accidents in Chinese Power Grid Based on Spearman's Correlation Coefficient and System Inertia .Proceedings of the Chinese Society for Electrical Engineering, 43(14), 5372-5381.
  13. Zhang, X. S., & Cai, B. Q. (2021). Corrosion prediction of submarine pipelines based on improved Random Forest model. China Safety Science Journal, 31(08), 69-74.
  14. Yu, Y., Wu, L. H., Zhang, F. Q., et al. (2022). Soft Sensing of Billet Shell Thickness Based on Improved Chaotic PSO Algorithm. Control Engineering of China, 29(04), 581-586.
  15. Shen, Y., Li, L. Q., Huang, F., et al. (2021). Pointing Error Correction of Risley-Prism System Based on Particle Swarm Algorithm. Acta Optica Sinica, 41(24), 139-148.
  16. Xing, X. X. (2015). Research progress of particle swarm optimization algorithm(in Chinese). Data Communications, (03), 19-21.
  17. Yang, G. X. (2023). Research on loss prediction of UHV AC transmission lines based on artificial intelligence algorithm [Master's thesis]. Fuzhou University.