Research Article

Experimental Study on Strength and Pore Structure of Cement Mortar in Early Freezing Environment

Yongbo Yang1, Qing Sun2, Zhiyun Wang2, Lishan Cui2, Yong Ding1,*
1. Harbin Institute of Technology
2. China Construction Third Engineering Bureau Co., Ltd.

* Corresponding author: [email protected]

Abstract

The pore structure of early freezing cement mortar was tested by mercury intrusion porosimetry. The pore size distribution and compressive strength of mortar with different water-cement ratio, curing period, age and temperature were studied. The effects of pore size distribution on the compressive strength with early freezing conditions were discussed. The results showed that both the short-term strength loss and the long-term strength loss were not serious in the negative temperature environment, and the negative temperature made the pore of 10-100nm increased, while reducing the 100-2000nm; The pore above 2000nm had little effect on the compressive strength and the pore of 10-2000nm played a major role in the effect of compressive strength, besides, the pore of 100-2000nm affected the long-term strength growth; Curing period affected the pore above 2000nm, the shorter the curing time, the higher the porosity in this range, and superplasticizer could significantly increase the pore above 2000nm.

Keywords: Early freezing; Cement mortar; Strength; Pore structure
Published: January 5, 2026
DOI: 10.54254/2755-2721/2026.31094
Volume: ACE Vol.216
pp. 138-146
Download PDF

References

  1. Ge, X. L., Ke, M. Y., Liu, W. B., & et al. (2024). The evolution law of freezing stress under concrete freeze-thaw action and its influence on frost resistance. Materials Reports, 38(12), 111-115.
  2. Liu, R. Q. (2011). A study on the critical frost resistance strength of concrete at low temperatures under multiple factors [Master's thesis]. Dalian University of Technology.
  3. Xue, J., Tang, M. S., & Lou, Z. H. (1985). Proceedings of the 7th International Congress on the Chemistry of Cement. China Architecture & Building Press.
  4. Şahin, Y., Akkaya, Y., & Taşdemir, M. A. (2021). Effects of freezing conditions on the frost resistance and microstructure of concrete. Construction and Building Materials, 270, 121458.
  5. Olivier, C. (2005). Poromechanics of freezing materials. Journal of the Mechanics and Physics of Solids, 53(8), 1689-1718.
  6. Corr, D. J., Juenger, M. C. G., Monteiro, P. J. M., & et al. (2004). Investigating entrained air voids and Portland cement hydration with low-temperature scanning electron microscopy. Cement and Concrete Research, 26(8), 1007-1012.
  7. Dong, Y. T., Meng, L., Lan, L., & et al. (2016). Study on the influence of concrete pore structure on frost resistance and mechanical properties under variable temperature curing. Railway Engineering, (3), 157-160.
  8. Han, W. Y., Zhu, W., Liu, M. L., & et al. (2016). A study on the strength development of cement at negative temperatures. Cement Engineering, (2), 12-14.
  9. Lin, W. G., Liu, L., Ye, H., & et al. (2025). Analyzing the influence of pore structure and vibration on clogging in pervious concrete. Journal of Cleaner Production, 495, 145065.
  10. Yang, J. H., Yuan, D. D., Huang, D. W., & et al. (2022). Effects of aggregate types and softening effect on multiaxial mechanical properties of lightweight aggregate concrete. Construction and Building Materials, 353, 128832.
  11. Du, X. L., & Jin, L. (2012). Study on the macro-mechanical properties of concrete considering the influence of pores and microcracks. Engineering Mechanics, 29(8), 101-107.
  12. Wang, Z. P., & Wang, T. (2013). A brief introduction to the principle and application of nuclear magnetic resonance freezing pore measurement method. Materials Reports, 27(1), 129-133.
  13. Ba, H. J., & He, Z. M. (1991). Formation and hydration of early structure of concrete at negative temperatures. Low Temperature Architecture Technology, (2), 46-48.