Research on Motion Heart Rate Detection Method Based on Photoplethysmography and Human Acceleration
Abstract
Heart rate is an important indicator reflecting the health status of the human body and has significant value in sports health monitoring. In order to solve the problem of motion artifacts interfering with the optical pulse wave recording (PPG) signal during motion, this paper describes PPG and proposes a deep convolutional attention network (DCan) method based on signal and human acceleration (ACC) signal fusion. This model uses multi-scale convolution and attention mechanism to extract features from PPG signal ACC and combines the complementary information of these two signal types to improve the accuracy of heart rate prediction. According to the experimental results, the average absolute error (MAE) of DCAN using the model to predict heart rate was reduced by 23% and 32% compared to the C-RNN model and NAS-PPG model, respectively, and showed higher stability and accuracy in various sports scenarios. This study provides reliable technical support for heart rate monitoring during exercise.
References
- Kamal A, Harness J, Irving G, et al. Skin photoplethysmography—A review. Computer Methods and Programs in Biomedicine, 1989, 28(4): 257–269.
- Fernandes R A, Vaz Ronque E R, Venturini D, et al. Resting heart rate: Its correlations and potential for screening metabolic dysfunctions in adolescents. BMC Pediatrics, 2013, 13: 1–7.
- Garber C E, Blissmer B, Deschenes M R, et al. Quantity and quality of exercise for developing and maintaining cardiorespiratory, musculoskeletal, and neuromotor fitness in apparently healthy adults: Guidance for prescribing exercise. Medicine & Science in Sports & Exercise, 2011, 43(7): 1334–1359.
- Biswas D, Simões-Capela N, Van Hoof C, et al. Heart rate estimation from wrist-worn photoplethysmography: A review. IEEE Sensors Journal, 2019, 19(16): 6560–6570.
- Zhang Z. Photoplethysmography-based heart rate monitoring in physical activities via joint sparse spectrum reconstruction. IEEE Transactions on Biomedical Engineering, 2015, 62(8): 1902–1910.
- Zhang Z, Pi Z, Liu B. TROIKA: A general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise. IEEE Transactions on Biomedical Engineering, 2014, 62(2): 522–531.
- Cotter S F, Rao B D, Engan K, et al. Sparse solutions to linear inverse problems with multiple measurement vectors. IEEE Transactions on Signal Processing, 2005, 53(7): 2477–2488.
- Hasan K, Chowdhury M H, Pathan N S, et al. Heart rate estimation from wrist PPG signal during intense physical exercise. SN Computer Science, 2023, 4(5): 684.
- Bahdanau D, Cho K, Bengio Y. Neural machine translation by jointly learning to align and translate. 2014.
- Vaswani A, Shazeer N, Parmar N, et al. Attention is all you need. Advances in Neural Information Processing Systems, 2017, 30.