Research Article

Freezing of Gait Prediction and Monitoring in the Treatment of Parkinson's Disease

Difei Lyu1,*, Zixuan Zhou2, Jiaxuan Song3
1. Boston University
2. University of Nottingham Ningbo China
3. Shihezi University

* Corresponding author: [email protected]

Abstract

Wearable sensing offers a promising path for continuous monitoring and early intervention of freezing of gait (FOG) in Parkin- son’s disease (PD), yet heterogeneity in sensor type/placement, ground- truthing, and validation metrics hampers comparability and transla- tion. This scoping review (1) catalogs sensor types and placements; (2) compares performance across sensor modalities and placements under comparable measurement regimes (with emphasis on accuracy) and analyzes how metric definitions shape results; and (3) identifies gaps for real-world deployment and standardization. We searched PubMed, Embase, IEEE Xplore, and Web of Science (2015–June 2025). Inclusion required a wearable approach targeting FOG/abnormal gait, at least one evaluation metric, and PD participants/data; two reviewers screened/extracted independently with third-party adju- dication. Across the studies summarized in Tables 1–3, wearable sensing for Parkinson’s disease (PD) freezing of gait (FOG) remains dominated by inertial measurement units (IMUs) with a variety of body placements (waist/lower-back, shank/ankle, foot, and multi-node configurations). According to the table, best accuracies locate roughly 71% to 99%, reflecting both differences in task definition (FOG detection, or broader gait abnormality) and heterogeneity in ground- truthing and validation protocols. A consistent pattern emerges: placement matters, and how we validate models strongly shapes apparent performance. We conclude FOG wearables are IMU-centric and placement-sensitive; standardizing labels/metrics and prioritizing subject-independent, home validation—alongside sparse, placement- optimized designs, >24-h runtime, on-device inference, privacy, and adherence/burden reporting—are key to translation.

Keywords: component; formatting; style; styling; insert.
Published: December 31, 2025
DOI: 10.54254/2755-2721/2026.TJ30921
Volume: ACE Vol.218
pp. 24-38
Download PDF

References

  1. N. Giladi, D. McMahon, S. Przedborski, E. Flaster, S. Guil- lory, V. Kostic, and S. Fahn, “Motor blocks in parkinson’s disease, ” Neurology, vol. 42, no. 2, pp. 333–333, 1992.
  2. S. K. Bansal, B. Basumatary, R. Bansal, and A. K. Sahani, “Techniques for the detection and management of freezing of gait in parkinson’s disease–a systematic review and future perspectives, ” MethodsX, vol. 10, p. 102106, 2023.
  3. R. Savica, B. R. Grossardt, J. H. Bower, J. E. Ahlskog, and  W. A. Rocca, “Incidence and pathology of synucleinopathies and tauopathies related to parkinsonism, ” JAMA neurology, vol. 70, no. 7, 2013.
  4. T. Pringsheim, N. Jette, A. Frolkis, and T. D. Steeves, “The prevalence of parkinson’s disease: a systematic review and  meta-analysis, ” Movement disorders, vol. 29, no. 13, pp. 1583–1590, 2014.
  5. T. Dua, Atlas: Country Resources for neurological disorders 2004: results of a Collaborative study of the World health organization and the World Federation of Neurology. World Health Organization, 2004.
  6. N. Giladi, R. Kao, and S. Fahn, “Freezing phenomenon in patients with parkinsonian syndromes, ” Movement disorders: official journal of the Movement Disorder Society, vol. 12, no. 3, pp. 302–305, 1997.
  7. I. Maidan, M. Plotnik, A. Mirelman, A. Weiss, N. Giladi, and J. M. Hausdorff, “Heart rate changes during freezing of gait in patients with parkinson’s disease, ” Movement disorders, vol. 25, no. 14, pp. 2346–2354, 2010.
  8. M. Macht, Y. Kaussner, J. C. Mo¨ller, K. Stiasny-Kolster, K. M. Eggert, H.-P. Kru¨ger, and H. Ellgring, “Predictors of freezing in parkinson’s disease: a survey of 6, 620 patients, ” Movement disorders, vol. 22, no. 7, pp. 953–956, 2007.
  9. R. B. Postuma, D. Berg, M. Stern, W. Poewe, C. W. Olanow,   W. Oertel, J. Obeso, K. Marek, I. Litvan, A. E. Lang et al., “Mds clinical diagnostic criteria for parkinson’s disease, ” Movement disorders, vol. 30, no. 12, pp. 1591–1601, 2015.
  10. D. Phan, M. Horne, P. N. Pathirana, and P. Farzanehfar, “Effect of Parkinsonism on Proximal Unstructured Movement Captured by Inertial Sensors, ” in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jul. 2018,   pp. 5507–5510, iSSN: 1558-4615. [Online]. Available: https: //ieeexplore.ieee.org/document/8513510/
  11. N. T. Pickle, S. M. Shearin, and N. P. Fey, “A machine learning approach to targeted balance rehabilitation in people with Parkinson’s disease using a sparse sensor set, ” in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jul. 2018, pp. 1202–1205, iSSN: 1558-4615. [Online]. Available: https: //ieeexplore.ieee.org/document/8512530/
  12. C. Carissimo, G. Cerro, G. Miele, H. Debelle, E. Packer,   Sarvestan, A. J. Yarnall, L. Rochester, L. Alcock,   L. Ferrigno, A. Marino, and S. Del Din, “A Novel Energy-Based Composite Index for Assessing Motor State in Parkinson’s Disease by Means of IMU-Based Digital Health Technology, ” in 2024 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), May 2024, pp. 1–6, iSSN: 2642-2077. [Online]. Available: https: //ieeexplore.ieee.org/document/10561000/
  13. J. Olmos and F. Mart´ınez, “A Riemannian Deep Learning Representation to Describe Gait Parkinsonian Locomotor Patterns, ” in 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Jul. 2022, pp. 3538–3541, iSSN: 2694-0604. [Online].  Available: https: //ieeexplore.ieee.org/document/9871206/
  14. L. Tao, X. Wang, X. Peng, P. Yang, J. Qi, and  Y. Yang, “Activity Selection to Distinguish Healthy People from Parkinson’s Disease Patients Using I-DA, ” in 2021 17th International Conference on Mobility, Sensing and Networking (MSN), Dec. 2021, pp. 66–73. [Online]. Available: https: //ieeexplore.ieee.org/document/9751465/
  15. C. Ricciardi, M. Amboni, C. De Santis, G. Ricciardelli,   G. Improta, G. Cesarelli, G. D’Addio, and P. Barone, “Classifying patients affected by Parkinson’s disease into freezers or non-freezers through machine learning, ” in 2020  IEEE International Symposium on Medical Measurements and Applications (MeMeA), Jun. 2020, pp. 1–6. [Online].  Available: https: //ieeexplore.ieee.org/document/9137317/
  16. W. Zhang, H. Sun, D. Huang, Z. Zhang, J. Li, C. Wu, Y. Sun,   M. Gong, Z. Wang, C. Sun et al., “Detection and prediction of freezing of gait with wearable sensors in parkinson’s disease, ” Neurological Sciences, vol. 45, no. 2, pp. 431–453, 2024.
  17. J. C. Vasquez-Correa, T. Arias-Vergara, P. Klumpp, P. A. Perez-Toro, J. R. Orozco-Arroyave, and E. No¨th, “End-2-End Modeling of Speech and Gait from Patients with Parkinson’s Disease: Comparison Between High Quality Vs. Smartphone Data, ” in ICASSP 2021 - 2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Jun. 2021, pp. 7298–7302, iSSN: 2379-190X. [Online]. Available: https: //ieeexplore.ieee.org/document/9414729/
  18. W. Huo, P. Angeles, Y. F. Tai, N. Pavese, S. Wilson,   M. T. Hu, and R. Vaidyanathan, “A Heterogeneous Sensing Suite for Multisymptom Quantification of Parkinson’s Disease, ” IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 28, no. 6, pp. 1397–1406, Jun. 2020. [Online]. Available: https: //ieeexplore.ieee.org/document/9064818/
  19. F. Parisi, G. Ferrari, M. Giuberti, L. Contin, V. Cimolin,   C. Azzaro, G. Albani, and A. Mauro, “Inertial BSN-Based Characterization and Automatic UPDRS Evaluation of the Gait Task of Parkinsonians, ” IEEE Transactions on Affective Computing, vol. 7, no. 3, pp. 258–271, Jul. 2016. [Online].  Available: https: //ieeexplore.ieee.org/document/7445833/
  20. A. Zampogna, L. Borz`ı, D. Rinaldi, C. A. Artusi, G. Im- balzano, M. Patera, L. Lopiano, F. Pontieri, G. Olmo, and  A. Suppa, “Unveiling the Unpredictable in Parkinson’s Dis- ease: Sensor-Based Monitoring of Dyskinesias and Freezing of Gait in Daily Life, ” Bioengineering (Basel), vol. 11, no. 5,   p. 440, Apr. 2024.
  21. A. Antonini, H. Reichmann, G. Gentile, M. Garon, C. Tedesco, A. Frank, B. Falkenburger, S. Konitsiotis, K.  Tsamis, G. Rigas, N. Kostikis, A. Ntanis, and C. Pattichis, “Toward objective monitoring of Parkinson’s disease motor symptoms using a wearable device: wearability and perfor- mance evaluation of PDMonitor®, ” Front Neurol, vol. 14, p. 1080752, 2023.
  22. T. Lencioni, M. Meloni, T. Bowman, A. Marzegan,   A. Caronni, I. Carpinella, A. Castagna, V. Gower, M. Ferrarin, and E. Pelosin, “Events Detection of Anticipatory Postural Adjustments through a Wearable Accelerometer Sensor Is Comparable to That Measured by the Force Platform in Sub- jects with Parkinson’s Disease, ” Sensors (Basel, Switzerland), vol. 22, no. 7, p. 2668, Mar. 2022.
  23. S. Mazilu, A. Calatroni, E. Gazit, A. Mirelman, J. M. Haus- dorff, and G. Tro¨ster, “Prediction of Freezing of Gait in Parkinson’s From Physiological Wearables: An Exploratory Study, ” IEEE journal of biomedical and health informatics, vol. 19, no. 6, pp. 1843–1854, Nov. 2015.
  24. M. Sun, W. Jung, K. Koltermann, G. Zhou, A. Wat- son, G. Blackwell, N. Helm, L. Cloud, and I. Pretzer- Aboff, “Parkinson’s Disease Action Tremor Detection with Supervised-Leaning Models, ” IEEE Int Conf Connect Health Appl Syst Eng Technol, vol. 2023, pp. 1–10, Jun. 2023.
  25. C. Diep, J. O’Day, Y. Kehnemouyi, G. Burnett, and H. Bronte- Stewart, “Gait Parameters Measured from Wearable Sensors Reliably Detect Freezing of Gait in a Stepping in Place Task, ”  Sensors (Basel, Switzerland), vol. 21, no. 8, p. 2661, Apr. 2021.
  26. L. L. Y. Chan, S. Yang, M. Aswani, L. Kark, E. Henderson,   S. R. Lord, and M. A. Brodie, “Development, Validation, and Limits of Freezing of Gait Detection Using a Single Waist- Worn Device, ” IEEE transactions on bio-medical engineering, vol. 71, no. 10, pp. 3024–3031, Oct. 2024.
  27. J. D. Delgado-Tera´n, K. Hilbrants, D. Mahmutovic´, A. L. Silva de Lima, R. J. A. v. Wezel, and T. Heida, “Ankle sensor-based detection of freezing of gait in parkinson’s disease in semi-free living environments, ” Sensors, vol. 25, no. 6, 2025. [Online]. Available: https: //www.mdpi.com/1424- 8220/25/6/1895
  28. J. O’Day, M. Lee, K. Seagers, S. Hoffman, A. Jih-Schiff, Kidzin´ski, S. Delp, and H. Bronte-Stewart, “Assessing inertial measurement unit locations for freezing of gait detection and patient preference, ” J Neuroeng Rehabil, vol. 19, no. 1, p. 20, Feb. 2022.
  29. P. Pierleoni, A. Belli, O. Bazgir, L. Maurizi, M. Paniccia, and  Palma, “A smart inertial system for 24h monitoring and classification of tremor and freezing of gait in parkinson’s disease, ” IEEE Sensors Journal, vol. 19, no. 23, pp. 11 612–11 623, 2019.
  30. H. Zach, A. M. Janssen, A. H. Snijders, A. Delval, M. U. Ferraye, E. Auff, V. Weerdesteyn, B. R. Bloem, and  J. Nonnekes, “Identifying freezing of gait in parkinson’s disease during freezing provoking tasks using waist- mounted accelerometry, ” Parkinsonism Related Disorders, vol. 21, no. 11, pp. 1362–1366, 2015. [Online]. Available:
  31. J. Seuthe, A. Heinzel, F. Hulzinga, P. Ginis, K. E. Zeuner, G. Deuschl, N. D’Cruz, A. Nieuwboer, and C. Schlenstedt, “Towards a better understanding of anticipatory postural ad- justments in people with Parkinson’s disease, ” PLOS ONE, vol. 19, no. 3, Mar. 2024. https: //www.sciencedirect.com/science/article/pii/S13538020150044323
  32. P. Pallavi, A. Raghuvanshi, S. D. Kumar, N. Patel, M. Kanetkar, R. Chhatlani, M. Rana, S. Betai, R. Rajan, and U. Lahiri, “On-demand cueing sensitive to step variability: Understanding its impact on gait of individuals with parkin- son’s disease, ” IEEE Journal of Translational Engineering in Health and Medicine, vol. 13, pp. 183–192, 2025.
  33. P. Pallavi, N. Patel, M. Kanetkar, and U. Lahiri, “Character- izing freezing of gait episodes for parkinson’s disease using a wearable device quantifying gait and posture, ” Journal of Medical and Biological Engineering, vol. 43, no. 3, pp. 266– 277, 2023.
  34. N. Naghavi and E. Wade, “Towards real-time prediction of freezing of gait in patients with parkinson’s disease: a novel deep one-class classifier, ” IEEE Journal of Biomedical and Health Informatics, vol. 26, no. 4, pp. 1726–1736, 2021.
  35. I. Mazzetta, A. Zampogna, A. Suppa, M. Pessione, and F. Ir- rera, “Toward a quantitative evaluation of the fall risk using the fusion of inertial signals and electromyography with wearable sensors, ” in 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII). IEEE, 2019,   pp. 2227–2230.
  36. A. Marcante, R. Di Marco, G. Gentile, C. Pellicano, F. As- sogna, F. E. Pontieri, G. Spalletta, L. Macchiusi, D. Gatsios,   A. Giannakis et al., “Foot pressure wearable sensors for freezing of gait detection in parkinson’s disease, ” Sensors,   vol. 21, no. 1, p. 128, 2020.
  37. M. Mancini, N. Hasegawa, D. S. Peterson, F. B. Horak, and J. G. Nutt, “Digital measures of freezing of gait across the spectrum of normal, non-freezers, possible freezers and definite freezers, ” Journal of Neurology, vol. 270, no. 9, pp. 4309–4317, 2023.
  38. N. Caballol, A` . Baye´s, A. Prats, M. Mart´ın-Baranera, and  P. Quispe, “Feasibility of a wearable inertial sensor to assess motor complications and treatment in parkinson’s disease, ” PLoS One, vol. 18, no. 2, p. e0279910, 2023.
  39. P. Lorenzi, R. Rao, G. Romano, A. Kita, M. Serpa, F. Filesi,   R. Parisi, A. Suppa, M. Bologna, A. Berardelli et al., “Smart sensing systems for the detection of human motion disorders, ” Procedia Engineering, vol. 120, pp. 324–327, 2015.
  40. R. Liu, Z. Wang, H. Zhao, S. Qiu, C. Wang, X. Shi, and F. Lin, “Quantitative analysis of lower limb motion in parkinson’s disease based on inertial sensors, ” IEEE Sensors Journal, vol. 22, no. 21, pp. 20 937–20 946, 2022.
  41. C. Liu, L. Han, S. Chang, and J. Wang, “An accelerometer- based wearable multi-node motion detection system of freez- ing of gait in parkinson’s disease, ” in 2022 IEEE International Instrumentation and Measurement Technology Conference (I2MTC). IEEE, 2022, pp. 1–5.
  42. K. Koltermann, W. Jung, G. Blackwell, A. Pinney, M. Chen,   L. Cloud, I. Pretzer-Aboff, and G. Zhou, “Fog-finder: Real- time freezing of gait detection and treatment, ” in Proceedings of the 8th ACM/IEEE international conference on connected health: applications, systems and engineering technologies, 2023, pp. 22–33.
  43. K. Koltermann, J. Clapham, G. Blackwell, W. Jung, E. N. Burnet, Y. Gao, H. Shao, L. Cloud, I. Pretzer-Aboff, and G. Zhou, “Gait-guard: Turn-aware freezing of gait detection for non-intrusive intervention systems, ” in 2024 IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE). IEEE, 2024, pp. 61–72.
  44. A. Kita, P. Lorenzi, R. Rao, and F. Irrera, “Reliable and robust detection of freezing of gait episodes with wearable electronic devices, ” IEEE Sensors Journal, vol. 17, no. 6, pp. 1899–1908, 2017.
  45. D. Huang, C. Wu, Y. Wang, Z. Zhang, C. Chen, L. Li,   W. Zhang, Z. Zhang, J. Li, Y. Guo et al., “Episode-level prediction of freezing of gait based on wearable inertial sig- nals using a deep neural network model, ” Biomedical Signal Processing and Control, vol. 88, p. 105613, 2024.
  46. H. Ghayvat, M. Awais, R. Geddam, M. T. Quasim,   S. A. Khowaja, and K. Dev, “Aicaregaitrehabilitation: Multi- modalities sensor data fusion for ai-iot enabled realtime elec- trical stimulation device for pre-fog and post-fog to person with parkinson’s disease, ” Information Fusion, vol. 122, p. 103155, 2025.
  47. F. C. G. Di Zubiena, A. Zampognav, M. Patera, G. Cusolito,   I. Mileti, A. Cannuli, A. Suppa, M. Paoloni, Z. Del Prete, and  E. Palermo, “Stride length and foot clearance measurements in parkinson patients through imu wearable sensors, ” in 2024 IEEE International Symposium on Medical Measurements and Applications (MeMeA). IEEE, 2024, pp. 1–6.
  48. G. Prateek, I. Skog, M. E. McNeely, R. P. Duncan, G. M. Earhart, and A. Nehorai, “Modeling, detecting, and track- ing freezing of gait in parkinson disease using inertial sen- sors, ” IEEE Transactions on Biomedical Engineering, vol. 65, no. 10, pp. 2152–2161, 2017.
  49. D. Ahn, H. Chung, H.-W. Lee, K. Kang, P.-W. Ko, N. S.  Kim, and T. Park, “Smart gait-aid glasses for parkinson’s dis- ease patients, ” IEEE Transactions on Biomedical Engineering, vol. 64, no. 10, pp. 2394–2402, 2017.