Research Article

Feasibility of Using Flexible Pressure Sensors for Medical Monitoring

Sirui Li*
University of Edinburgh

* Corresponding author: [email protected]

Abstract

Growing demand for unobtrusive, continuous physiological monitoring in healthcare, rehabilitation and home settings highlights the need for thin, comfortable, and accurate pressure sensing. This paper investigates a flexible, multilayer Inductor-capacitor pressure sensor and a portable readout scheme for medical detection. The study aims to verify whether resonant-frequency shifts of the sensor can be robustly converted to pressure values outside laboratory conditions. This study derives a closed-form mapping from a parallel-plate and axial-compression model, then implements a portable frequency-sweep readout (frequency response analyzer with directional coupler) to track resonance. Bench measurements on prototype sensors use baseline/load tests, narrowband sweeps, and Lorentzian fitting to estimateQ,frand uncertainty; results are compared with conventional instrumentation to assess agreement. The findings show identifiable amplitude dips and phase transitions near resonance, allowing frequency estimation with low dispersion and thus reliable pressure reconstruction after calibration. The portable pathway reduces cost and deployment complexity while maintaining practical accuracy, supporting applications such as abdominal respiration tracking and compression-therapy feedback. Overall, the work demonstrates the feasibility of flexible LC sensors coupled with a portable readout for clinical and home pressure monitoring.

Keywords: Resonant frequency; Compression therapy; Sensor; Inductor-capacitor circuit
Published: November 26, 2025
DOI: 10.54254/2755-2721/2026.KA30031
Volume: ACE Vol.209
pp. 107-114
Download PDF

References

  1. K. Munirathinam, et al. “Recent progress on flexible capacitive pressure sensors, ” Advanced Materials Technologies, 2021.
  2. B. Xu, et al. “Radio-frequency resonator-based flexible wireless sensors for biomedical applications, ” Micromachines, 2022.
  3. A. Sachdeva, et al. “Graduated compression stockings for prevention of deep vein thrombosis, ” Cochrane Database of Systematic Reviews, 2018/2021 update.
  4. C. Qian, et al. “Wireless and battery-free LC sensor for interstitial fluid pressure monitoring, ” Biosensors and Bioelectronics, 2024.
  5. W.-J. Deng, L.-F. Wang, L. Dong, Q.-A. Huang. “LC wireless sensitive pressure sensors with microstructured PDMS dielectric layers for wound monitoring, ” IEEE Sensors Journal, 2018.
  6. Z. Sun, et al. “Flexible wireless passive LC pressure sensor: design methodology and cost-effective preparation, ” Micromachines, 2021.
  7. H. Kou, et al. “Wireless wide-range pressure sensor based on graphene/PDMS sponge, ” Scientific Reports, 2019.
  8. S. Charkhabi, et al. “Monitoring wound health through bandages with passive LC sensors, ” ACS Sensors, 2020.
  9. S. Li, et al. “Iontronic-capacitance-enhanced LC wireless passive pressure sensor, ” Applied Physics Letters, 2023.
  10. F. Caspers. “RF engineering basic concepts: S-parameters, ” CERN Note, 2012.
  11. S. Amakawa, et al. “Demystifying complex-referenced S-parameters, ” IEICE Transactions on Electronics, 2016.