Application of Sensors Used to Detect Degree of Anesthesia during Surgery
Abstract
Medical sensors act as an important role in modern surgeries. They help operation become safer and easier to operate. This paper goes into sensors made of electronic plastic design specially for detecting degree of anesthesia during surgery. Determine degree of anesthesia is a crucial part during surgery. Serious consequences may be caused if depth of anesthesia is not precise. The paper begins by introducing electronic plastics—such as polypyrrole and polythiophene, which are conjugated polymers with alternating single and double covalent bonds enabling electrical conductivity. Detecting method according to BIS index and concentration of propofol in patient blood are two ways used in surgery. Structure of the device is also included. Due to the interference in the blood, the two methods combined to work better. One example of clinical trials in The First Affiliated Hospital of Chengdu Medical College has validated its efficiency in improving surgical safety and anesthesia quality. In the future, such electronic plastic sensors are expected to be further optimized to provide more convenient technical support for surgical anesthesia monitoring.
References
- Smith, G., D'Cruz, J. R., Rondeau, B., & Goldman, J. (2023). General anesthesia for surgeons. In StatPearls. StatPearls Publishing.
- Gao Rong Awa.(2020). Preparation and testing methods of polythiophene nanocomposites. Chemical Industry Management, (30), 35-36.
- Jiahao Liu.(2023). Research on Flexible Medical Sensors Based on Conductive Polymer Composite Hydrogels (Master's Thesis, Dalian University of Technology). Master
- Zhiwei Wang, Xiaoyu Yang &Enpin Zhang.(2023). Working principle and common fault handling of bispectral index anesthesia depth monitoring system. China Medical Equipment, 20(09), 192 - 194.
- Taorui Jie, Xueran Ma , Da Chen , Junhui Liang & Xiang Ding.(2024). Research on the Detection Method of Anesthesia Depth Monitoring Equipment. Measurement Science and Technology, 68(05), 32 - 36.
- Jilin Zhang &Dalei Zhang.(2006). GC/MS detection of the general anesthetic propofol in blood. (eds.) Abstracts of the 25th Annual Academic Conference of the Chinese Chemical Society (Volume 2) (pp. 845). Criminal Technology Corps of the Public Security Department of Heilongjiang Province
- Fanhui Zhang.(2025). Research on Flexible Electrochemical Sensors and Systems for Physiological Multi-parameter Detection (Master's Thesis, Beijing University of Chemical Technology). Master
- Yuhei Mae1* and Michiyoshi Sanuki 1(2025) Anesthesia information system–assisted detection and effective management of sugammadex-induced anaphylaxis: a case report
- Jingfeng Li, Zhengyuan shi , Mengjie Zhang, Lei Guan & Dechun Zhang.(2024). Establishment of a detection method for propofol blood concentration and its application in patients with lymphedema. China Pharmacy, 35(04), 476 - 480