Research Article

A Hybrid Analog-Digital Circuit Framework for Enhanced Cycle-by-Cycle Fourier Series Analysis: Motion Artifact Mitigation in Photoplethysmography Signal Acquisition

Xinqi Liu*
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China, 200240

* Corresponding author: [email protected]

Abstract

Pulse oximeters need to collect light signals at red and infrared (IR) wavelengths to measure how much oxygen is in a patient's blood. Patient motion induces motion artifacts in PPG signals, introducing significant computational errors. Cycle-by-Cycle Fourier Series Analysis (CFSA) has been demonstrated as an effective method for eliminating motion artifact interference in Photoplethysmography (PPG) signals. This paper explores methods to obtain sufficiently accurate cycle periods to reduce CFSA result errors and proposes an approach combining high-pass filtering with differential amplifier circuitry for preprocessing raw PPG signals to enhance cycle period detection. The experimental results confirm the effectiveness of the proposed method, demonstrating that the Signal-to-Total Noise Band Ratio (SNBR_dB) of PPG signals was increased from 0.53 dB to 5.90 dB, while the linearity improved from 1.13 to 4.39. Furthermore, this study extends the utilization of analog integrated circuits for motion artifact mitigation in biomedical signal processing.

Keywords: Hybrid analog-digital circuit; Cycle-by-cycle Fourier series analysis (CFSA); Photoplethysmography (PPG); Motion artifact mitigation; Signal processing.
Published: July 24, 2025
DOI: 10.54254/2755-2721/2025.PO25393
Volume: ACE Vol.178
pp. 22-30
Download PDF

References

  1. Northrop, B. R. (2019). Noninvasive instrumentation and measurement in medical diagnosis. CRC Press.
  2. Nitzan, M., Romem, A., & Koppel, R. (2014). Pulse oximetry: Fundamentals and technology update. Medical Devices (Auckland), 7, 231-239. doi: 10.2147/MDER.S47319. PMID: 25031547; PMCID: PMC4099100.
  3. Ram, M. R., Madhav, K. V., Krishna, E. H., Nagarjuna Reddy, K., & Reddy, K. A. (2011). On the performance of time varying step-size least mean squares (TVS-LMS) adaptive filter for motion artifact reduction from PPG signals. In 2011 International Conference on Communications and Signal Processing (pp. 431-435). Kerala, India. doi: 10.1109/ICCSP.2011.5739353.
  4. Naraharisetti, K. V. P., & Bawa, M. (2011). Comparison of different signal processing methods for reducing artifacts from photoplethysmograph signal. In 2011 IEEE International Conference on Electro/Information Technology (pp. 1-8). Mankato, MN, USA. doi: 10.1109/EIT.2011.5978571.
  5. Reddy, K. A., George, B., & Kumar, V. J. (2009). Use of Fourier series analysis for motion artifact reduction and data compression of photoplethysmographic signals. IEEE Transactions on Instrumentation and Measurement, 58(5), 1706-1711. doi: 10.1109/TIM.2008.2009136.
  6. Reddy, K. A., George, B., & Kumar, V. J. (2008). Motion artifact reduction and data compression of photoplethysmographic signals utilizing cycle by cycle Fourier series analysis. In 2008 IEEE Instrumentation and Measurement Technology Conference (pp. 176-179). Victoria, BC, Canada. doi: 10.1109/IMTC.2008.4547026.
  7. Relente, A. R., & Sison, L. G. (2002). Characterization and adaptive filtering of motion artifacts in pulse oximetry using accelerometers. In Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society (pp. 1769-1770). Houston, TX, USA.doi: 10.1109/IEMBS.2002.1106644.
  8. Lee, C. M., & Zhang, Y. T. (2003). Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach. In IEEE EMBS Asian-Pacific Conference on Biomedical Engineering (pp. 194-195). Kyoto, Japan. doi: 10.1109/APBME.2003.1302650.
  9. Kim, B. S., & Yoo, S. K. (2006). Motion artifact reduction in photoplethysmography using independent component analysis. IEEE Transactions on Biomedical Engineering, 53(3), 566-568. doi: 10.1109/TBME.2005.869784.
  10. Bracewell, R. N. (2000). The Fourier transform and its applications. McGraw-Hill.
  11. Jarchi, D., & Casson, A. J. (2017). Description of a database containing wrist PPG signals recorded during physical exercise with both accelerometer and gyroscope measures of motion. Data, 2, 1. https: //doi.org/10.3390/data2010001.