Research Article

Core Sheath Fiber Based Photoplethysmography (PPG) Integration and Artificial Intelligence (AI) Outlook: A Non-Invasive Scheme for Infant Heart Rate Monitoring

Qi Yao*
The High School affiliated to Inner Mongolia Normal University, Hohhot, Inner Mongolia, China, 010000

* Corresponding author: [email protected]

Abstract

Photoplethysmography (PPG) is a non-invasive physiological monitoring technology used in health monitoring, but traditional devices have limitations in infant health monitoring. This paper aims to improve the comfort and reliability of infant health monitoring by combining PPG with core-sheath textile technology. Core-sheath structural fibers are used as carriers for PPG sensors, resulting in non-invasive and comfortable heart rate monitoring. Signal processing algorithms like wavelet transform, ICA, and CNN are used to denoise PPG signals and extract heart rate. The proposed theory outperforms traditional methods in signal quality and heart rate detection accuracy, while improving wearing comfort. The PPG signal processing algorithm and AI interaction enable real-time heart rate monitoring, providing an innovative solution for infant health monitoring.

Keywords: Core-sheath fiber; Photoplethysmography (PPG); Artificial Intelligence (AI); Infants and young children; Heart rate monitoring; Non-invasive
Published: April 21, 2025
DOI: 10.54254/2755-2721/2025.22244
Volume: ACE Vol.150
pp. 71-76
Download PDF

References

  1. Jianhan,H, Yanxin,Y, Huabing W, Xiaohu W, Xiao H, Advances in the Application of One-Dimensional Structured Flexible Strain Sensors in Smart Textile and Apparel Products, 2096 - 1928( 2024) 05 - 0456 - 08DOI:10.20205/j.cnki.2096-1928.2024.05.009
  2. Zhenzhen,L, Yanmei,L, Development of ECG Signal Applications in Smart Clothing, 1674-2346(2024)03-0049-07
  3. Luis Cuadros, MBBS, Hilmy Ismail, MD, FRCA, FANZCA,and Kwok Ho, PhD Original Research Evaluation of Reliability of MYZONE MZ-3 Heart Rate Monitor:A Study for the Future of Telephysiotherapy for Preoperative Prehabilitation in Cancer Patients
  4. Ann Transl Med 2019;7(17):417 | http://dx.doi.org/10.21037/atm.2019.06.79
  5. Castaneda, D., Esparza, A., Ghamari, M., Soltanpur, C., & Nazeran, H. (2018). "A review on wearable photoplethysmography sensors and their potential future applications in health care." International Journal of Biosensors & Bioelectronics, 4(4), 195-202.
  6. Allen, J. (2007). Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 28(3), R1-R39.
  7. Xiangfeng,Z, Research on Heart Rate Estimation Algorithm of PPG Signal under Human Movement State [D]. Anhui University of Technology,2023.DOI:10.26918/d.cnki.ghngc.2023.000266.
  8. Peng et al.: Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter. BioMedical Engineering OnLine 2014 13:50.
  9. KAVSAOĞLU, AHMET REŞİT; POLAT, KEMAL; and BOZKURT, MEHMET RECEP (2016) "An innovative peak detection algorithm for photoplethysmography signals: an adaptive segmentation method," Turkish Journal of Electrical Engineering and Computer Sciences: Vol. 24: No. 3, Article 76. https://doi.org/ 10.3906/elk-1310-177
  10. Argüello-Prada, E.J.; Castillo García, J.F. Machine Learning Applied to Reference Signal-Less Detection of Motion Artifacts in Photoplethysmographic Signals: A Review. Sensors 2024, 24, 7193. https://doi.org/10.3390/s24227193
  11. https://www.msdmanuals.cn/home/children-s-health-issues/miscellaneous-disorders-in-infants-and-young-children/sudden-infant-death-syndrome-sids
  12. 2024 Data and Statistics for SUID and SIDS https://www.cdc.gov/sudden-infant-death/data-research/data/index.html
  13. 2024 Neonatal mortality ratehttps://www.who.int
  14. www.youlai.cn/video/article/0AAE0DTuPu.html