Research Article

Stability Analysis of Prestressed Cable - Supported Tank Shell Roof

Meinan Zhang*, Zubin Zhang, Xingjiang Liu
College of Pipeline and Civil Engineering, China University of Petroleum(East China), Qingdao, China

* Corresponding author: [email protected]

Abstract

With the growth of energy demand, storage tanks are developing towards larger capacities. During this process, the stability of latticed tank tops is facing severe challenges. Based on the dome structure formed by prestressed cables combined with single-layer spherical latticed shells used in modern architectural structures, this paper applies it to the storage tanks in the petroleum industry, forming a new type of storage tank latticed tank top structure composed of prestressed cables combined with the single-layer latticed shell of the tank top, aiming to improve the stability of the tank dome. Static and stability analyses of the storage tank latticed tank top structure are carried out from aspects such as different cable layout methods, different magnitudes and positions of prestress. The results show that the storage tank latticed tank top with prestressed cables has better performance than the traditional single-layer latticed tank top without prestressed cables in terms of displacement, internal force distribution of members, and ultimate bearing capacity under the same working load. At the same time, the influence laws of prestress magnitude and position on the storage tank latticed tank top structure are obtained, and reasonable suggestions are given.

Keywords: Single-layer spherical shell; Prestressed cable; Storage tank dome; Stability analysis
Published: March 20, 2025
DOI: 10.54254/2755-2721/2025.21553
Volume: ACE Vol.144
pp. 29-34
Download PDF

References

  1. Y.F. Zhang, S.X. Shi, Yan Li, Research Review on the Dome Shell Structure of Large - scale Storage Tanks, Contemporary Chemical Industry, Contemporary Chemical Industry, 50 (8) (2021) 5.
  2. D.C. Li, Static Stability and Local Failure Sensitivity Analysis of Kiewitt-Lamella Type Single-layer Lattice Shell Structure, South China University of Technology, 2020.
  3. J. Cai, Q. Q. Liu, S. He, Z.R. Jiang, Static Stability Analysis of Kiewitt-Lamella Single-Layer Lattice Shell, in: 23rd National Academic Conference on Structural Engineering, Gansu, China, October 2014 pp. II-205-II-210.
  4. D.H. Lu, J.H. Su, J.C. Chen, et al. Development and Prospects of Prestressed Engineering Construction Technology in China, Architecture Technology, 49 (6) (2018), 4.
  5. S.L. Dong, Y. Zhao, The application and development of pretensioned long-span steel space structures in China, Elsevier, (2002) 15-26,
  6. S.L. Dong, Development History, Innovation, Form Classification and Practical Application of Spatial Structures, Spatial Structures, 15 (03) (2009) 22-43.
  7. W.J. Kang, Z.H. Chen, Heung-Fai Lam, C.R. Zuo, Analysis and design of the general and outmost-ring stiffened suspen-dome structures, Engineering Structures, (2003) 1685-1695,
  8. B. Shekastehband, K. Abedi, Chenaghlou M.R. Chenaghlou, Sensitivity analysis of tensegrity systems due to member loss, Journal of Constructional Steel Research, 67 (9) (2011) 1325-1340.
  9. S.Z. Shen, Design formulas for stability analysis of reticulated shells, Advances in Steel Structures, Elsevier, (1999) 51-62.
  10. T. Suzuki, T. Ogawa, K. Ikarashi, Elasto-plastic buckling analysis of rigidly jointed single layer reticulated domes, International Journal of Space Structures, 7(4) (1992) 363-368.