Passive Design Optimization of Shading Devices in Temperate Climate Zone Method and Case Studies
Abstract
This study explores the design thinking behind passive design strategies for building performance optimization, such as shading devices, and demonstrates an integrated workflow. A culinary school in Asheville, North Carolina, is used as a case study. The region has a temperate continental climate with warm, humid summers and cold winters with occasional snowfall. Parametric modeling was performed using the Pollination plug-in in Rhino, and energy simulation was performed using DesignBuilder, while daylight analysis was performed using Ladybug. In order to verify the performance of shading devices in this temperate climate, this study simulated and analyzed a variety of shading design schemes to compare their effectiveness in reducing solar heat gain and improving indoor thermal comfort. The simulation results show that the modified recessed window shading device performs better throughout the year than the original design (solar gain 1876.76 kWh, average radiant temperature 24.37°C), with solar gain reduced to 1426.34 kWh and the average radiant temperature reduced to 22.61°C. In contrast, the horizontal and vertical fixed shade has a solar gain of 1293.59 kWh and an average radiant temperature of 22.31°C. shading device is slightly better than the horizontal and vertical fixed shading devices. The building perfor-mance-oriented design process attempted in this study effectively combines design and performance optimization by integrating a parametric tool and energy consumption simulation software, which helps incorporate building energy efficiency improvements into the building design stage while also providing a quantitative basis for the design of shading devices in temperate climates.
References
- L. G. Valladares-Rendón, G. Schmid, and S.-L. Lo, “Review on energy savings by solar control techniques and optimal building orientation for the strategic placement of façade shading systems,” Energy and Buildings, vol. 140, pp. 458–479, Apr. 2017, doi: 10.1016/j.enbuild.2016.12.073.
- S. Subhashini and K. Thirumaran, “A passive design solution to enhance thermal comfort in an educational building in the warm humid climatic zone of Madurai,” Journal of Building Engineering, vol. 18, pp. 395–407, Jul. 2018, doi: 10.1016/j.jobe.2018.04.014.
- X. Gong, C. Jia, Y. Yu, and C. Li, “Optimization of passive design measures for residential buildings in Chinese hot summer and cold winter areas,” IOP Conf. Ser.: Earth Environ. Sci., vol. 310, no. 2, p. 022058, Aug. 2019, doi: 10.1088/1755-1315/310/2/022058.
- M. Efthymiou, P. R. Kontonis, A. Leonidou, G. Kazanakis, and C. Vassiliades, “Investigation of Sun Protection Issues via the Active and Passive Building Integration of Active Solar Energy Systems: A Case Study of the Renovation of an Existing Building in Cyprus,” IOP Conf. Ser.: Earth Environ. Sci., vol. 410, no. 1, p. 012063, Jan. 2020, doi: 10.1088/1755-1315/410/1/012063.
- L. G. Valladares-Rendón and S.-L. Lo, “Passive shading strategies to reduce outdoor insolation and indoor cooling loads by using overhang devices on a building,” Build. Simul., vol. 7, no. 6, pp. 671–681, Dec. 2014, doi: 10.1007/s12273-014-0182-7.
- M. S. Shahdan, S. S. Ahmad, and M. A. Hussin, “External shading devices for energy efficient building,” IOP Conf. Ser.: Earth Environ. Sci., vol. 117, p. 012034, Feb. 2018, doi: 10.1088/1755-1315/117/1/012034.
- M. Talaei and H. Sangin, “Multi-objective optimization of energy and daylight performance for school envelopes in desert, semi-arid, and mediterranean climates of Iran,” Building and Environment, vol. 255, p. 111424, May 2024, doi: 10.1016/j.buildenv.2024.111424.
- C. W. Kwon and K. J. Lee, “Integrated Daylighting Design by Combining Passive Method with DaySim in a Classroom,” Energies, vol. 11, no. 11, p. 3168, Nov. 2018, doi: 10.3390/en11113168.
- Z. Tian, X. Zhang, X. Jin, X. Zhou, B. Si, and X. Shi, “Towards adoption of building energy simulation and optimization for passive building design: A survey and a review,” Energy and Buildings, vol. 158, pp. 1306–1316, Jan. 2018, doi: 10.1016/j.enbuild.2017.11.022.