Measurement and Suppression Techniques for Leakage Current in Photovoltaic Inverters: Topology Enhancements and Carrier Modulation Optimization
Abstract
With the widespread use of electronic equipment across various industries, the impact of leakage current on such equipment has garnered increasing attention. Issues such as circuit aging and equipment instability caused by leakage current are becoming increasingly concerning. As a result, measuring and mitigating leakage current has become a critical aspect of the design and testing of electronic equipment. This paper reviews the current techniques for leakage current measurement and suppression. Firstly, two primary methods for leakage current measurement are introduced: the first is the capacitive leakage current measurement method, which utilizes a polarized high-voltage source and current measurement module; the second is the indirect measurement method, which measures the voltage across a resistor to infer the leakage current. Following this, the paper discusses various techniques for suppressing leakage current, including methods for improving circuit structures and optimizing switching drive circuits. Finally, the advantages and disadvantages of each method are summarized, along with an assessment of their potential applications. This review aims to provide valuable insights into future research and engineering practice related to leakage current measurement and suppression.
References
- Chen, A., Qiang, Y., Yin, Z., & Wang, R. (1999). The problems and solutions of the leakage current checking in medical electrical equipments. Zhongguo Yi Liao Qi Xie Za Zhi = Chinese Journal of Medical Instrumentation, 23(3), 149-152.
- Aguada, S., Rodriguez, C., Vanella, O., & Bruni, R. (2013). Development of a leakage current meter using differential method. IEEE Latin America Transactions, 11, 149-154.
- Lorenz, D., Barke, M., & Schlichtmann, U. (2014). Monitoring of aging in integrated circuits by identifying possible critical paths. Microelectronics Reliability, 54, 1075-1082.
- Youyuan, W. (2008). Power grid voltage measurement based on the leakage current of capacitive equipments. Automation of Electric Power Systems.
- Ma, X., Li, W., Wang, X., Yang, M., Gao, Z., & Zhao, Y. (2018). Calibration of measuring network of leakage current tester by high frequency current source. 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), 1-2.
- Franklin, R. (1990). An exploration of leakage current. 40th Conference Proceedings on Electronic Components and Technology, 1002-1007 (Vol. 2).
- Zhu, X., Wang, H., Sun, R., Wang, H., Zhang, W., Deng, X., & Yue, X. (2021). Leakage current suppression of single-phase five-level inverter for transformerless photovoltaic system. IEEE Transactions on Industrial Electronics, 68, 10422-10435.
- Guo, X., Zhou, J., He, R., Jia, X., & Rojas, C. (2018). Leakage current attenuation of a three-phase cascaded inverter for transformerless grid-connected PV systems. IEEE Transactions on Industrial Electronics, 65, 676-686.
- Guo, X., Yang, Y., He, R., Wang, B., & Blaabjerg, F. (2019). Transformerless Z-source four-leg PV inverter with leakage current reduction. IEEE Transactions on Power Electronics, 34, 4343-4352.
- Liang, W. H., Liu, Y. S., Ge, B. M., et al. (2019). Night operation, analysis, and control of single-phase quasi-Z-source photovoltaic power system. IET Renewable Power Generation, 13(15), 2817-2829.
- Yang, D., Yang, K., & Gao, F. (2023). Topology optimization analysis of leakage current suppression in three-level four-leg photovoltaic grid-connected inverter. IEEE Access, 11, 50145-50156.
- Zhang, L., Zou, Y., Xing, Y., Zhuge, H., Mo, W., & Zheng, Z. (2023). A common-mode voltage reduction DPWM scheme for three-phase three-level inverters with unbalanced neutral-point voltage. IECON 2023 - 49th Annual Conference of the IEEE Industrial Electronics Society, 1-5.
- Jayakumar, V., Chokkalingam, B., & Munda, J. (2021). A comprehensive review on space vector modulation techniques for neutral point clamped multi-level inverters. IEEE Access, 9, 112104-112144.