Seismic Resilience Evaluation and Improvement of Confined Masonry Structures Using Finite Element Analysis and the N2 Method
Abstract
Confined masonry combines concrete columns and beams with brick walls to form a building structural system. Confined masonry offers good seismic performance, easy construction, and component reuse, making it popular in earthquake-prone areas. Meanwhile, The N2 method is a nonlinear static analysis technique designed to assess the performance and load-carrying capacity of building structures under seismic loads. By integrating elements of structural dynamic analysis with pushover analysis, it provides a simplified yet reliable tool for evaluating structural behavior. This method is particularly effective for seismic design and evaluating a building's ability to withstand earthquake forces. The purpose of this paper is to evaluate the seismic resilience of the current confined masonry building by utilizing finite element software and pertinent regulations. The examination identifies design flaws and evaluates the seismic capacity of the structure using the N2 method. Furthermore, the study presents corrective measures, which are re-evaluated and contrasted against the finite element software and N2 method outcomes. The results demonstrate that the confined masonry building, improved according to the recommendations in this paper, ultimately meets the seismic requirements of relevant regulations and is deemed feasible through N2 analysis.
References
- Porter, K. (2015). A Beginner’s Guide to Fragility, Vulnerability, and Risk. Revised 23 December 2015. University of Colorado Boulder and SPA Risk LLC, Denver CO USA.
- Earthquake Engineering Research Institute. (2011). Seismic design guidelines for low-rise confined masonry buildings. Earthquake Engineering Research Institute. On April 4, 2023, obtained from https://www.eeri.org/lfe/pdf/confinedmasonry.pdf.
- CEN, 1994, Eurocode 8 - Design provisions for earthquake resistance of structures, European prestandards ENV 1998, European Committee for Standardization, Brussels.
- BSI. (2005). BS EN 1996-1-1:2005 Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures. British Standards Institution
- Fajfar, P. (2000). A Nonlinear Analysis Method for Performance Based Seismic Design. Earthquake Spectra, 16(3), 573-592.
- ATC, 1996, Seismic evaluation and retrofit of concrete buildings, Vol. 1, ATC 40, Applied Technology Council, Redwood City, CA.
- Federal Emergency Management Agency. (2006). NEHRP recommended provisions for seismic regulations for new buildings and other structures. FEMA P-750. Federal Emergency Management Agency. On April 4, 2023, obtained from https://www.fema.gov/media-library-data/20130726-1650-20490-4429/fema750_complete.pdf.