A novel solar-assisted air source heat pump system for urban renewal: Experimental test and numerical simulation
Abstract
Old residential communities require novel heating solutions to meet heating demands sustainably. In Southern China, current heating systems in old communities have high energy costs and lack sustainability. A potential solution, air source heat pumps (ASHP), have evaporators susceptible to frost accumulation and poor heating performance at low ambient temperatures. This study proposes a hybrid design that uses additional solar thermal energy to improve energy gains from the air source; the innovative serial coupling design increases the air-source temperature by engineering the evaporator of the ASHP as the load-side of the heat exchanger. The novel hybrid design aims to be efficient, cost-effective, and sustainable, satisfying urban redevelopment needs. A prototype of the novel hybrid solar-assisted ASHP system was constructed; various performance parameters were evaluated, and system operation in extreme climates was simulated in TRNSYS. Results indicated that the novel hybrid system had significantly superior heating performance, delivering a 70.1% improvement in heating rate compared to single-source ASHP under lower ambient temperatures (13°C). The novel hybrid system also had a high COP value between 5.7 and 6.3, significantly exceeding values of 2.3-3.5 for most air-conditioning units. It demonstrates consistent performance in all simulated climates. It is estimated that the novel hybrid system can save 1000 RMB in annual energy costs for an average Shanghai family and reduce Shanghai’s CO2 emissions by 4.7 million tons. The novel system addressed limitations of ASHP, optimizing performance while maintaining sustainability, offering a promising solution for urban renewal projects in China.
References
- Hall, Casey. Why Shanghai’s oldest neighbourhood has to shiver each winter. (2018, January 4). South China Morning Post. https://www.scmp.com/news/china/society/article/2126825/why-shanghais-oldest-neighbourhood-has-shiver-each-year-through
- Nie, Y., Bu, Z., & Yang, J. (2017). Discussion on heating strategies in winter of residential buildings in Shanghai aiming at ultra-low energy target. Procedia Engineering, 205, 3130–3137.
- Environment, U. N. (2022, November 9). 2022 Global Status Report for Buildings and Construction. UNEP - UN Environment Programme. https://www.unep.org/resources/publication/2022-global-status-report-buildings-and-construction
- CO2 emissions from buildings and construction hit new high, leaving sector off track to decarbonize by 2050: UN. (2022, November 9). UN Environment. http://www.unep.org/news-and-stories/press-release/co2-emissions-buildings-and-construction-hit-new-high-leaving-sector
- Heat Pumps - Energy System. IEA. https://www.iea.org/energy-system/buildings/heat-pumps
- Wang, X., Xia, L., Bales, C., Zhang, X., Copertaro, B., Pan, S., & Wu, J. (2020). A systematic review of recent air source heat pump (ASHP) systems assisted by solar thermal, photovoltaic and photovoltaic/thermal sources. Renewable Energy, 146, 2472–2487. https://doi.org/10.1016/j.renene.2019.08.096
- Research shows huge heat pump potential in china. (n.d.). CLASP. Retrieved 23 December 2023, from https://www.clasp.ngo/updates/research-shows-huge-heat-pump-potential-in-china/
- https://doi.org/10.1016/j.proeng.2017.10.134
- Cai, J., Zhou, H., Xu, L., Shi, Z., Zhang, T., & Ji, J. (2022). Energy and exergy analysis of a novel solar-air composite source multi-functional heat pump. Renewable Energy, 185, 32–46. https://doi.org/10.1016/j.renene.2021.12.033
- Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018). Review on improvement for air source heat pump units during frosting and defrosting. Applied Energy, 211, 1150–1170. https://doi.org/10.1016/j.apenergy.2017.12.022
- Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017). Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review. Applied Thermal Engineering, 113, 1071–1087. https://doi.org/10.1016/j.applthermaleng.2016.11.107
- Wen, B. (2018). Winter heating in Shanghai.Mechanical and Electrical Information, 546, 146-147.
- Solar water heaters. (n.d.). Energy.Gov. Retrieved 23 December 2023, from https://www.energy.gov/energysaver/solar-water-heaters
- Jouhri, M., Dhakar, P. (2019). A Review Study on Solar Water Heating Systems. Journal of Emerging Technologies and Innovative Research. https://www.researchgate.net/publication/345002100_A_Review_Study_on_Solar_Water_Heating_Systems
- Dong, S., Xu, T., & Chen, M. (2022). Solar radiation characteristics in shanghai. Journal of Physics: Conference Series, 2351(1), 012016. https://doi.org/10.1088/1742-6596/2351/1/012016
- Liu, Y., Zhang, H., & Chen, H. (2020). Experimental study of an indirect-expansion heat pump system based on solar low-concentrating photovoltaic/thermal collectors. Renewable Energy, 157, 718–730. https://doi.org/10.1016/j.renene.2020.05.090
- Yerdesh, Ye., Abdulina, Z., Aliuly, A., Belyayev, Ye., Mohanraj, M., & Kaltayev, A. (2020). Numerical simulation on solar collector and cascade heat pump combi water heating systems in Kazakhstan climates. Renewable Energy, 145, 1222–1234. https://doi.org/10.1016/j.renene.2019.06.102
- Esfandeh, S., Hemmat Esfe, M., & Kamyab, M. H. (2022). Chapter 11—Applications of nanofluids in solar energy collectors focusing on solar stills. In H. M. Ali (Ed.), Advances in Nanofluid Heat Transfer (pp. 341–373). Elsevier. https://doi.org/10.1016/B978-0-323-88656-7.00010-6
- Yao, J., Chen, E., Dai, Y., & Huang, M. (2020). Theoretical analysis on efficiency factor of direct expansion PVT module for heat pump application. Solar Energy, 206, 677–694. https://doi.org/10.1016/j.solener.2020.04.053