Research Article

Numerical simulation of forced ventilation fire suppression for wing leading edge pool fires

Shaoqiang Wu, Jie Bai*
China Civil Aviation University

* Corresponding author: [email protected]

Abstract

In order to meet the requirements of the flammable liquid fire prevention regulations under AC25-863, which stipulates that in the event of ignition, the ignition and its harm of leaked flammable liquids should be minimized, this study investigates the impact on the aircraft structure and the suppression process of wing leading edge pool fires of flammable liquid leakage under forced ventilation fire suppression. Geometric modeling of the wing leading edge in the flammable liquid leakage area is performed, and the burning conditions of the flame under different conditions are simulated. The heat release rate per unit area of the pool fire surface is set to 396.67 kW/m², with ventilation speeds ranging from 0 to 3.1 m/s. Through the analysis of simulation charts and data, it is observed that as the forced ventilation rate increases, the pool fire gradually tends towards a trend of suppression

Keywords: Wing Leading Edge; Pool Fire; Fr Number; Fire Suppression
Published: May 23, 2024
DOI: 10.54254/2755-2721/65/20240520
Volume: ACE Vol.65
pp. 288-297
Download PDF

References

  1. Williams F. Progress in knowledge of flamelet structure and extinction[J]. Progress in Energy and Combustion Science,2000,26(4):657-682.
  2. Jiang P, Lu S. Pool Fire Mass Burning Rate and Flame Tilt Angle under Crosswind in Open Space[J]. Procedia Engineering,2016,135261-274.
  3. Li, H., Tian, L., Zeng, G., et al. (2022). Study on the Impact of Wind Speed on the Spread Pattern of Mine Fire Based on FDS. China Safety Science Journal, 18(05), 143-149.
  4. Yu, Z. Q. (2022). Reaction Kinetics Analysis and Simulation Application of Combustion Mechanism of RP-3 Aviation Kerosene. (Doctoral dissertation). Jiangsu University. DOI:10.27170/d.cnki.gjsuu.2022.000791
  5. Zeng, J. (2016). Numerical Simulation of Open Space Aviation Kerosene Pool Fire. (Master’s thesis). Harbin Engineering University.
  6. Huang, Y., Zhang, H. W., Shen, R. Y., et al. (2019). Experimental Study on Combustion Characteristics of Inhibited Diesel Pool Fire. China Journal of Safety Science, 29(08), 55-60. DOI:10.16265/j.cnki.issn1003-3033.2019.08.009
  7. Shanbhogue J S, Husain S, Lieuwen T. Lean blowoff of bluff body stabilized flames: Scaling and dynamics[J]. Progress in Energy and Combustion Science,2008,35(1):98-120.