Research Article

Current research on exoskeletal lower limb rehabilitation robots

Zhihao Wei*
Shenyang Institute of Science and Technology

* Corresponding author: [email protected]

Abstract

Stroke is characterized by a high incidence rate, and walking is one of the essential human functions. Lower limb rehabilitation robots can offer safe and effective walking training to patients with walking impairments caused by conditions such as neural injuries, aiding in their recovery or assisting in walking. For the needs of patients themselves, restoring their physical state and motor function as much as possible is the primary purpose of rehabilitation, and rehabilitation efficiency is an important factor affecting the quality of life of patients after surgery. Research on exoskeleton robots varies both domestically and internationally, each with its own unique characteristics and features. This paper outlines the design of lower limb rehabilitation robots based on gait analysis and control methods. It also provides an overview of the current state of research on lower limb exoskeleton robots in terms of degrees of freedom, actuation methods, and clinical applications. Furthermore, it offers insights into future directions for research on lower limb exoskeleton robots.

Keywords: Stroke; Exoskeleton Robots; Rehabilitation Robots; Rehabilitation Training
Published: May 20, 2024
DOI: 10.54254/2755-2721/62/20240447
Volume: ACE Vol.62
pp. 289-297
Download PDF

References

  1. Fang, Y. (2009). Research on dynamic analysis and control of the wearable power assist robot [Doctoral dissertation]. University of Science and Technology of China.
  2. Shuai, M. (2018). A biped lower-limb exoskeleton rehabilitation robot (CN3048224985) [Patent]. September 18, 2018.
  3. Wang, Z. B., Chen, S. J., Yang, Q., et al. (2021). Progress in clinical rehabilitation of lower extremity exoskeleton robot. Chinese Journal of Rehabilitation Medicine, 36(6), 761-765.
  4. Miao, Y. J. (2015). Research on the mechanical performance design of an innovative lower extremity exoskeleton [Doctoral dissertation]. Shanghai Jiao Tong University.
  5. Zhang, C. (2016). Research on lower limbs powered exoskeleton robot [Doctoral dissertation]. Harbin Institute of Technology.
  6. Jin, X. L. (2017). Control system research of hydraulic driven lower limb exoskeleton in swing phase [Doctoral dissertation]. Zhejiang University.
  7. Zhao, X. G., Tan, X. W., Zhang, B. (2020). Development of soft lower extremity exoskeleton and its key technologies: A survey. Robot, 42(3), 365-384.
  8. Liuwang, Z. Y., Zheng, Y. H., Sun, J. Q., et al. (2021). Design and performance experiment of a lightweight flexible lower-limb exoskeleton. Robot, 43(4), 433-442.
  9. Buffalo Robot Technology (Chengdu) Co., Ltd. (2019). Buffalo Rehabilitation Robot Product Introduction [Webpage]. http://www.buffalo-robot.com/show-25-35-1.html
  10. Shanghai Fourier Intelligent Technology Co., Ltd. (2019). Fourier X2 Product Introduction [Webpage]. http://www.fftai.com/product/X2.php. Li, J., Zhu, L. Y., Gou, X. F. (2018). Survey on exoskeleton lower limbs rehabilitation robot and key technologies. Chinese Medical Equipment Journal, 39(8), 95-100.
  11. Reinkensmeyer, D. J., Aoyagi, D., Emken, J. L., et al. (2006). Tools for understanding and optimizing robotic gait training. Journal of Rehabilitation Research & Development, 43(5), 657-670.
  12. Hussain, S., Xie, S. Q., Jamwal, P. K. (2013). Robust nonlinear control of an intrinsically compliant robotic gait training orthosis. IEEE Transactions on Systems, Man & Cybernetics, 43(43), 655-665.
  13. Kong, K., Jeon, D. (2006). Design and control of an exoskeleton for the elderly and patients. IEEE/ASME Transactions on Mechatronics, 11(4), 428-432.
  14. Carse, B., Meadows, B., Bowers, R., et al. (2013). Affordable clinical gait analysis: an assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system. Physiotherapy, 99(4), 347-351.
  15. Ekso Bionics. (2012, September 2). Ekso Lower limb rehabilitation robot [Webpage]. http://www.eksobionics.com/ekso
  16. Berkeley Bionics. (2009, February 26). Human Universal Load Carrier [Webpage]. http://bleex.me.berkeley.edu/research/exoskeleton/hulc/
  17. Chu, A. (2005). Design of the Berkeley lower extremity exoskeleton (BLEEX) [Doctoral dissertation]. University of California, Berkeley.
  18. Ghan, J., Kazerooni, H. (2006). System identification for the Berkeley lower extremity exoskeleton (BLEEX). In IEEE International Conference on Robotics and Automation Orlando (pp. 3477-3484).
  19. Zhao, Y. N., Hao, Z. W., Li, J. M., et al. (2012). The effect of Lokomat lower limb gait training rehabilitation robot on balance function and walking ability in hemiplegic patients after ischemic stroke. Chinese Journal of Rehabilitation Medicine, 27(11), 1015-1020.
  20. Feng, X. X., Bai, Y. H., Xu, Y. M., et al. (2014). Effectiveness of lower limb exoskeletons rehabilitation robot in improving lower limb function of stroke patients. Chinese Journal of Rehabilitation, 29(2), 86-88.