Research Article

Simulation of translational motion correction during cartesian brain MRI

Jingxin Zhang*
Qingdao No.58 High School

* Corresponding author: [email protected]

Abstract

Brain Magnetic Resonance Imaging (MRI) is invaluable for non-invasively capturing detailed anatomical and functional information. However, motion artifacts, particularly during brain imaging, can compromise the precision of scans. This study explores motion correction techniques, focusing on the widely-used PROPELLER method and its application to Golden-angle Cartesian Randomized Time-resolved (GOCART) acquisition. While PROPELLER effectively corrects in-plane translation and rotation, its use with cartesian data demands increased sampling. GOCART, a high-speed cartesian sampling scheme, has shown promise in Dynamic Contrast-Enhanced (DCE) MRI, yet its specific artifacts in brain imaging remain underexplored. Our simulation framework assesses PROPELLER correction for translational motion in GOCART-sampled data, examining two motion directions, varied frequencies, and different temporal resolutions. Serving as a vital pre-clinical testing tool, this platform contributes to the optimization of motion correction algorithms, addressing challenges and refining imaging protocols for enhanced diagnostic reliability in advanced brain MRI.

Keywords: MRI; motion; PROPELLER
Published: March 19, 2024
DOI: 10.54254/2755-2721/48/20241658
Volume: ACE Vol.48
pp. 280-285
Download PDF

References

  1. Rosenbloom MJ, Pfefferbaum A. Magnetic resonance imaging of the living brain: evidence for brain degeneration among alcoholics and recovery with abstinence. Alcohol Res Health. 2008;31(4):362-376.
  2. Godenschweger F, Kägebein U, Stucht D, et al. Motion correction in MRI of the brain. Phys Med Biol. 2016;61(5):R32-R56. doi:10.1088/0031-9155/61/5/R32
  3. Boussel L, Herigault G, de la Vega A, Nonent M, Douek PC, Serfaty JM. Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI. J Magn Reson Imaging. 2006;23(3):413-415. doi:10.1002/jmri.20525
  4. Hennig J. K-space sampling strategies. Eur Radiol. 1999;9(6):1020-1031. doi:10.1007/s003300050788
  5. Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999;42(5):963-969. doi:10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l
  6. Zhu Y, Guo Y, Lingala SG, Lebel RM, Law M, Nayak KS. GOCART: GOlden-angle CArtesian randomized time-resolved 3D MRI. Magn Reson Imaging. 2016;34(7):940-950. doi:10.1016/j.mri.2015.12.030