Artificial intelligence in clinical applications
Abstract
Modern medicine has improved to the point that intelligent diagnostic tools and auxiliary medical technology, such as surgical robots and image analysis systems, are now widespread in clinical settings. In clinical practice, the performance of different surgical robots and image analysis systems is very different, which seriously limits the use of complex medical scenes. The algorithm models and robotic arms that these intelligent robots and the supporting systems rely on have being recognized by the researchers. In this study, hardware and software algorithms are introduced one at a time, with a focus on the Da Vinci medical robot arm systems, the control mechanisms that run the surgical task optimization tools, in particular Proportional-Integral-Derivative (PID) and Remote Center of Motion (RCM), and the image algorithm active contour model that significantly increased the accuracy of tumor localization. Also provided are suggestions for improving the system's use, its limits, and future research possibilities.
References
- Pransky, J. (1997). ROBODOC‐surgical robot success story. Industrial Robot: An International Journal, 24(3), 231-233.
- Zhao, W., Shen, L., Islam, M. T., Qin, W., Zhang, Z., Liang, X., ... & Li, X. (2021). Artificial intelligence in image-guided radiotherapy: a review of treatment target localization. Quantitative Imaging in Medicine and Surgery, 11(12), 4881.
- Bawaadam, H., Benn, B. S., Colwell, E. M., Oka, T., & Krishna, G. (2023). Lung Nodule Marking With ICG Dye–Soaked Coil Facilitates Localization and Delayed Surgical Resection. Annals of Thoracic Surgery Short Reports.
- Antoniou, G. A., Riga, C. V., Mayer, E. K., Cheshire, N. J., & Bicknell, C. D. (2011). Clinical applications of robotic technology in vascular and endovascular surgery. Journal of vascular surgery, 53(2), 493-499.
- Kass, M., Witkin, A., & Terzopoulos, D. (1988). Snakes: Active contour models. International journal of computer vision, 1(4), 321-331.
- Penza, V., De Momi, E., Enayati, N., Chupin, T., Ortiz, J., & Mattos, L. S. (2017). EnViSoRS: Enhanced vision system for robotic surgery. A user-defined safety volume tracking to minimize the risk of intraoperative bleeding. Frontiers in Robotics and AI, 4, 15.
- Dehghani, M., Moghadam, M. M., & Torabi, P. (2017). Analysis, optimization and prototyping of a parallel RCM mechanism of a surgical robot for craniotomy surgery. Industrial Robot: An International Journal, 45(1), 78-88.
- Shi, H., Liang, Z., Zhang, B., & Wang, H. (2023). Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot. Sensors, 23(4), 2361.
- Li, Y., Ang, K. H., & Chong, G. C. (2006). PID control system analysis and design. IEEE Control Systems Magazine, 26(1), 32-41.
- Tian, X., & Xu, Y. (2020). Low delay control algorithm of robot arm for minimally invasive medical surgery. IEEE Access, 8, 93548-93560.
- Lanfranco, A. R., Castellanos, A. E., Desai, J. P., & Meyers, W. C. (2004). Robotic surgery: a current perspective. Annals of surgery, 239(1), 14.
- Hockstein, N. G., Nolan, J. P., O'Malley Jr, B. W., & Woo, Y. J. (2005). Robotic microlaryngeal surgery: a technical feasibility study using the daVinci surgical robot and an airway mannequin. The Laryngoscope, 115(5), 780-785.
- Taylor, G. W., & Jayne, D. G. (2007). Robotic applications in abdominal surgery: their limitations and future developments. The International Journal of Medical Robotics and Computer Assisted Surgery, 3(1), 3-9.
- Arata, J., Takahashi, H., Pitakwatchara, P., Warisawa, S. I., Tanoue, K., Konishi, K., ... & Hashizume, M. (2007, April). A remote surgery experiment between Japan and Thailand over Internet using a low latency CODEC system. In Proceedings 2007 IEEE international conference on robotics and automation (pp. 953-959). IEEE.